Enviro EG 40 B owner manual Deciding Where to Locate Your Stove, Dimensions, Clearances

Models: EG 40 B

1 20
Download 20 pages 40.91 Kb
Page 4
Image 4

DECIDING WHERE TO LOCATE YOUR STOVE

DIMENSIONS:

Front Width:

25"/ 63 cm

Rear Width:

25"/ 63 cm

Height:

29"/

74 cm*

Depth

21"/

53 cm

( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg

CLEARANCES:

FIG. 1

A. Side wall to stove

12"/ 30cm

B. Rear wall to stove

4"/ 10cm

C. Combustible to stove Top

36”/ 91cm

D. Floor to stove

0"/ 0cm

E. Corner clearance

2"/ 5cm

F. Alcove depth

48"/ 122cm

Maintain sufficient clearances

 

for service and maintenance

 

FIG. 2

The stove should be located out of traffic and away from furniture and draperies.

The stove should have sufficient access for its safe operation and maintenance.

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building. e.g. cutting a wall or ceiling joist.

The stove can be installed on any standard flooring materials. i.e. Wood, carpet or linoleum.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6ft. (1.8m) of the stove.

These stoves can be installed in bedrooms.

(IN CANADA: must be installed with a listed wall thermostat)

(IN USA: see current ANSI Z223.1 for installation instructions.)

The flow of combustion and ventilation air must not be obstructed.

4

Page 4
Image 4
Enviro EG 40 B owner manual Deciding Where to Locate Your Stove, Dimensions, Clearances