Setup & Operation 4. Setting of End Effectors
G10 / G20 Rev.2 49
Automatic speed setting by Weight
G10 series
140
120
100
80
60
40
20
0 1 2 3 4 5 6 7 8 9 10 (kg)
Weight setting
(
%
)
100 100 100 100 90
70
100
G10-85***
* The percentage in the graph
is based on the speed at
rated weight (5 kg) as 100%.
G20 series
140
120
100
80
60
40
20
0 5 10 15 20 (kg)
Weight setting
(
%
)
120 120
100
80 70 G20-A0***
* The percentage in the graph
is based on the speed at
rated weight (10 kg) as 100%.
Contact us for details of G10-65*** and G20-85***.