Table 5

 

 

(cont.)

 

 

Signal

Return

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

Signal

 

 

IDirection

 

 

 

 

Description

 

Pin No.

! Pin No.

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

-

 

 

 

NC

 

 

 

 

 

 

 

 

Not used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 to30

-

 

 

 

GND

 

 

 

 

 

 

 

 

TWISTED-PAIR

RETURN signal GND level.

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the level of this signal becomes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“LOW”, the printer controller is reset to its

 

31

-

 

 

 

lNlT

 

 

 

In

 

 

 

initial state and the print buffer is cleared.

 

 

 

 

 

 

 

 

 

 

This signal is normally at “HIGH” level, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

its pulse width must be more than 56~s at

 

 

 

 

 

 

 

 

 

 

--

 

 

 

 

 

the receiving terminal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The level of this signal becomes “LOW”

 

 

 

 

 

 

 

 

 

 

 

 

out

 

 

 

when the printer is in -

 

32

 

 

 

 

ERROR

 

 

 

 

 

 

 

1. PAPER END state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. OFF-LINE state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Error state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

-

 

 

 

GND

 

-

 

 

 

 

Same as with Pin Nos. 19 to 30.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

-

 

 

 

NC

 

 

 

 

 

 

 

 

Not used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulled up to +5V through 4.7KD resistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data entry to the printer is possible only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

when the level of this signal is “LOW”.

 

36

-

 

 

SLCT IN

 

 

 

 

In

 

(Internal fixing

can be carried out with DIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 1-8. The condition at the time of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shipment is set “LOW’ for this signal.)

NOTES: 1. “Direction” refers to the direction of signal flow as viewed from the printer.

2.“Return” denotes “TWISTED PAIR RETURN” and is to be connected at signal ground level.

As to the wiring for the interface, be sure to use a twisted-pair cable for each signal and never fail to complete connection on the Return side. To prevent noise effectively, these cables should be shielded and con- nected to the chassis of the host computer and the printer, respec- tively.

3.All interface conditions are based on TTL level. Both the rise and fall times of each signal must be less than 0.2 /.Ls.

4.Data transfer must not be carried out by ignoring the ACKNLG or BUSY signal. (Data transfer to this printer can be carried out only after con- firming the ACKNLG signal or when the level of the BUSY signal is “LOW”.)