The foIlowing shows an example program used when the drawer connected to
the drawer drive signal 1 is driven using an ON time of 200 ms.
PRINT #1, CHR$(&H1B);ā€œPā€;CHR$(0);CHR$
GOSUB*WAlT3OOMS
*WAlT3OOMS
ON time 200ms OFF time 500ms
300[ms] wait routine (* NOTE)
RETURN
NOTE: *This part is indicated in Formula D-3. Set this value so that it
can satisfy
Formula
D-3 (or provides an internal processing time
at least as long as the wait routine time.)
When the drawer is driven according to the conditions above, the drive
waveform is as shown in Figure D-2.
ON
Figure D-2. Example Drawer Drive Signal Waveform
-73-