Printer Parts

 

2

3

1

Type B and

Single

two color

Type A

color

Type D

 

Type D

 

 

DIP Switch Tables

Serial

SW

Function

ON

OFF

 

 

 

 

1-1

Data reception

Ignored

Prints”?”

 

error

 

 

 

 

 

 

1-2

Receive buffer

40 bytes

ANK Model:

 

capacity

 

1000 bytes

 

 

 

 

Multilingual

 

 

 

 

model: 512 bytes

 

 

 

 

1-3

Handshaking

XON/XOFF

DTR/DSR

 

 

 

 

1-4

Word length

7 bits

8 bits

 

 

 

 

1-5

Parity check

Yes

No

 

 

 

 

1-6

Parity selection

Even

Odd

 

 

 

 

1-7

Baud rate

4800 bps

9600 bps

 

 

 

 

1-8

Busy condition

BUSY when

BUSY when

 

 

 

receive

offline or receive

 

 

 

buffer is full

buffer full

 

 

 

 

2-1

Print column

42/35

40/33

 

selection

 

 

 

7

9 font/

 

 

 

9

9 font

 

 

 

 

 

 

2-2

For internal use. Do not change.

 

 

 

2-3

Type A For internal use. Do not change.

 

 

 

 

 

Types B & D Pin 6

Enabled

Disabled

 

reset signal

 

 

 

 

 

 

2-4

Type A Undefind.

 

 

 

 

 

 

 

Types B & D Pin 25

Enabled

Disabled

 

reset signal

 

 

 

 

 

 

2-5,

For internal use. Do not change.

 

2-6

 

 

 

 

 

 

 

 

2-7

Type A Pin 6 reset

Enabled

Disabled

 

signal

 

 

 

 

 

 

 

Types B & D For internal use. Do not change

 

 

 

 

2-8

Type A Pin 25

Enabled

Disabled

 

reset signal

 

 

 

 

 

 

 

Types B & D Undefined.

 

 

 

 

 

 

Parallel

SW

Function

ON

OFF

 

 

 

 

1-1

Auto line feed

Enabled

Disabled

 

 

 

 

1-2

Receive buffer

40 bytes

ANK Model:

 

capacity

 

1000 bytes

 

 

 

 

Multilingual

 

 

 

 

model: 512 bytes

 

 

 

 

1-3-

Undefined

 

 

1-7

 

 

 

 

 

 

 

 

1-8

Busy condition

BUSY when

BUSY when offline

 

 

 

receive

or receive buffer

 

 

 

buffer is full

full

 

 

 

 

2-1

Print column

42/35

40/33

 

selection

 

 

 

7

9 font/

 

 

 

9

9 font

 

 

 

 

 

 

2-2

Internal use. Do not change.

 

 

 

2-3

Type A Internal use. Do not change.

 

 

 

 

Types B & D Defined.

 

 

 

 

2-4

Type A Undefined.

 

 

 

 

 

 

Types B & D Pin

Enabled

Disabled

 

31 reset signal

 

 

 

 

 

 

2-5,

For internal use. Do not change.

2-6

 

 

 

 

 

 

 

2-7

Type A Undefined.

 

 

 

 

Types B & D Internal use. Do not change.

 

 

 

 

2-8

Type A Pin 31

Enabled

Disabled

 

reset signal

 

 

 

 

 

 

 

Types B & D Undefined.

 

 

 

 

 

 

Page 2
Image 2
Epson U200 user manual Printer Parts, DIP Switch Tables