IIIKeypad Functions

I.Keys setting and keypad layout

The lower name on the key is the basic function and the function of the upper name on the key can be executed simultaneously by pressing <shift> key.

1

2

3

4

CALIBRAT

 

 

 

COMM

MODE

TYPE

TYPE

E

CONTRAST

OFF

ON/RES

 

TRANS

 

CANCEL

VERIFY

BRIGHT

 

ET

 

 

 

 

 

 

 

 

5

6

7

8

WT LIMIT

TARE

 

 

ACCUM

MEMO

MEMO

TOTAL

SET

PRESET

DELETE

ENTER

 

RECALL

CLEAR

CLEAR

WT LIMIT

TARE WT

EXIT

WEIGH

 

 

 

 

 

 

 

 

SHIFT

9

0

 

 

LIST PR

MARK

TIME

MINUS

GW/NW

DIVISION

TYPE SIGN

PAPER

PR

MODIFY

 

WT

 

TARE

ZERO

ROLL

PRINT

 

 

 

 

 

 

 

 

II. Keys functions

Notes: <xx><xx> represent keys series and <Figure keys> represents keys operation series, composed of <0><9>,<.>,<->,etc..<Shift>key perform <-> function when entering non-linearity edited value and category mark in upper name function state. In other cases, serve as switch between the upper name function and lower name function states.

1. <<On/ Reset>> Power on and reset. Self-checking begins upon powering on and then go to weighing display mode. The displayed value zeroed if the difference between present weight and preset zero point is within initial zero-setting range and the automatic zero-setting switch is on (p29=1), if without , <Err 50> appears and the last zero point remains.

2.<<Off>> Turn off the instrument.

3.<<Zero >> In gross weight and steady data state, this function works and present value return to zero, provided that conforming to relevant zero-setting range. Every first zero-setting is initial one upon powering on and zero-setting range is determined by P16 with 20(% Max) as default. After zero-setting,zero-setting range become ±2%Max of initial zero point.

4.<<GW/NW>>Switching between gross weight and net weight, tare data remains.

5.<<Tare>> In gross weight and steady data state, tare the present value and then go to net weight state.

6.<<Shift>><<Division>><<Figure Key>><<Enter>> Set division d, resume previous calibrated division after powering off.

7.<<Shift>><<Type sign>><<Figure Key>><<Enter>> A figure with any decimal digit and minus can be set to identify the category of present goods. This category mark can be printed by external printer only and internal printer can not print this category mark. Press <<Shift>><<Type sign>>to check category marks during operation.

8.<<PR>> Print present data. If present data is weight with category mark, it will be saved to weighing record and added into accumulation value. Only the displayed information