Ericsson LBI-39175A manual Control Unit, Ege

Models: LBI-39175A

1 24
Download 24 pages 48.7 Kb
Page 18
Image 18

LBI-39175A

 

 

CONTROL UNIT

 

 

 

 

 

SYMPTOM

 

DIAGNOSTIC PROCEDURE

 

 

 

Radio dead at power-on

a.

Check the battery connections and the Red lead A+ fuse on the power

(display dark and no

 

cable.

 

 

lighted indicators)

b.

Turn the unit "OFF," then simultaneously press and hold the

 

 

 

"EMERGENCY" and "OPTION" buttons, while turning the unit "ON."

 

 

All indicator lights and all display dots should light. Release the buttons

 

 

and the display should show the following message:

 

 

© - 1993

or

© - 1994

 

 

EGE

 

EGE

 

 

This indicates the Control Unit is functioning correctly. If this passes,

 

 

check programming and feature encryption, using "EDACS3" PC

 

 

Programming utility.

 

 

 

c.

If this fails, measure A+ voltage at MIC connector Pin 6 (referenced to

 

 

ground at Pin 7). If this fails, check fuse F601 on the Logic PWB for A+

 

 

on each side of the part. Replace the PWB if it is open circuited.

 

d.

If the fuse is OK, check the connection of the Flex Circuit PC2 with J701

 

 

on the Logic PWB. If this fails, reconnect PC2, making sure the side tabs

 

 

are locked. Re-check the MIC connector Pin 6 for A+.

 

e.

If this passes, check the programming and feature encryption, using

 

 

"EDACS3" PC Programming utility. If this symptom persists, substitute a

 

 

known good Logic PWB, and re-program.

 

 

f.

If no A+ is present at MIC Pin 7, check for A+ on the Logic PWB J704 Pin

 

 

3. If this fails, check the J704/J1004 connection. If this fails, replace the

 

 

PA module. If this passes, replace the Logic PWB.

 

 

 

The Display lights, then

a.

Turn the unit "OFF," then simultaneously press and hold the

goes dead.

 

"EMERGENCY" and "OPTION" buttons, while turning the unit "ON."

 

 

All the indicator lights and all display dots should light. Release the buttons

 

 

and the display should show the following message:

 

 

© - 1993

or

© - 1994

 

 

EGE

 

EGE

 

 

This indicates the Control Unit is functioning correctly. If this passes,

 

 

check programming and feature encryption, using "EDACS3" PC

 

 

Programming utility.

 

 

 

b.

If this passes, check the connection of the Flex Circuit PC2 with J701 on

 

 

the Logic PWB. If this passes re-connect it making sure the side tabs are

 

 

locked.

 

 

 

 

 

 

 

18

Page 18
Image 18
Ericsson LBI-39175A manual Control Unit, Ege