LBI-39175A

TRACKING DATA

The radio personality contains certain information bytes known as Tracking Data, which allow the radio computer to calibrate transmitter power, modulation deviation, and squelch threshold. Normally, no adjustments need be made to the radio to maintain specified limits for the above parameters, since the radio computer makes the necessary adjustments using the Tracking Data established at the factory. However, should Transmitter PA, Synthesizer, or Logic Circuit boards be replaced, it may be necessary to alter the Tracking Data to re-set these parameters properly.

Furthermore, if the Tracking Data is lost, specialized procedures are required to load new Tracking Data. therefore, it is VERY IMPORTANT to establish a record of the Tracking Data of every radio as it is received from the factory. The frequencies at which Tracking Data is established are given in the "Test Frequencies" section.

TEST FREQUENCIES

The following frequencies are those for which Tracking Data is established, and are used as Test Frequencies:

Table 2 - Tracking Data Frequencies (Low Split)

Parameter

RF Power

Modulation

Squelch Set

 

 

Deviation

 

f1L (MHz)

136.0000

136.0000

136.0000

f1H (MHz)

N/A

139.9950

N/A

f2L (MHz)

140.0050

140.0050

140.0050

f2H (MHz)

N/A

143.9950

N/A

f3L (MHz)

144.0050

144.0050

144.0050

f3H (MHz)

N/A

147.9950

N/A

f4L (MHz)

148.0050

148.0050

148.0050

f4H (MHz)

153.0000

153.0000

153.0000

 

 

 

 

Table 3 - Tracking Data Frequencies (High Split)

 

 

 

 

 

Parameter

RF Power

Modulation

Squelch Set

 

 

Deviation

 

f1L (MHz)

150.0000

150.0000

150.0000

f1H (MHz)

N/A

155.4950

N/A

f2L (MHz)

155.5050

155.5050

155.5050

f2H (MHz)

N/A

161.4950

N/A

f3L (MHz)

161.5050

161.5050

161.5050

f3H (MHz)

N/A

167.4950

N/A

f4L (MHz)

167.5050

167.5050

167.5050

f4H (MHz)

174.0000

174.0000

174.0000

 

 

 

 

9

Page 9
Image 9
Ericsson LBI-39175A manual Tracking Data, Test Frequencies