Essick Air SAD150 Maintenance, Pulley And Belt Adjustments, Spring Start-Up, Winter Shut Down

Models: AS20012 SAD10012 AS10012 AD100 AD20012 AS150 SAD150 SAS150 AD15012 SAS15012 AD150 SAS10012 SAD15012 AS15012 AU20012 SAD100 SAS100 AD10012 AS100

1 16
Download 16 pages 63 Kb
Page 3
Image 3
Pulley And Belt Adjustments
Fig. 9
Remove
Base
Fig. 6
Decrease
Amperage

keep float from turning. Place nut

 

 

8

 

 

(4) and ferrule (3) on water supply

 

 

 

 

line. Connect to float fitting and

 

 

 

 

3 4

tighten until water tight. Turn on

 

 

1

2

 

water supply and check for leaks.

 

5

 

 

 

 

 

 

Loosen screw (6) and adjust rod

7

 

 

 

 

(7) until water level is within 1” of

6

9

 

 

top of reservoir. Tighten screw (6).

 

Fig. 5

 

 

 

Slide float shield (8) over float body

 

 

 

 

 

 

 

 

 

(5) until it snaps into place.

Bleed-Off.Use of the bleed-off kit is recommended to prevent scale build up by bleeding off small amounts of circulating water during operation. Do not add any type of water treatment chemicals to the water since they may damage the evaporative media.

Pulley And Belt Adjustments

Pulley adjustment. With an ammeter, check the motor amperage. Adjust the pulley until the amperage draw on the motor is just below that specified on the motor nameplate. To

adjust the pulley, loosen the adjustment set screw and rotate the sheave. Tighten the set screw so that it is over a flat area, otherwise thread damage will occur. To increase amperage draw, increase pulley diameter. To decrease amperage draw, decrease pulley diameter (see Fig. 6). Recheck belt alignment.

MaintenanceCAUTION: Always check the amperage of the motor after ad- justing pulley to be certain it does not exceed the amperage stamped on the motor specification plate. Improper pulley adjustment will overload and burn out the motor.

Belt tension. Loosen the motor mount

3 Lb.

3/4 Inches

bolts and slide the motor back until the

 

belt is properly tensioned. A 3 lb. force

 

should deflect the belt 3/4 inches (see

 

Fig. 7). Retighten motor mount bolts.

Fig. 7

Do not adjust pulley to tighten belt.

Maintenance

Spring Start-UpWARNING: Before doing any maintenance be sure to disconnect from power source. This is for your safety.

Spring Start-Up

Belt tension. Check belt tension and readjust if needed.

Grease bearings. The blower bearings in this unit should be greased once a year with a good grade of ball bearing grease.

Cleaning pads. A clean pad is more absorbent, efficient and will give more cool air. Annually, or when required, using a garden hose with nozzle, back wash to clean out the openings, then clean off the inlet face any scale or other obstruction to the passages. Slight scraping may be required to remove hardened scale.

Pad replacement. The pads should be replaced after 5 years or if necessary. To change pads, remove top access panel, remove grill, and disconnect water delivery tube. Remove water distributor holder and lift out media sections. Replace with the same type media. You can purchase them from your dealer.

IMPORTANT: In order to get the best performance from your cool- ing pads, they must be installed properly. If you have purchased a pad with two equal angles, the following instructions can be disregarded. Pads must always be installed with the steeper flute angle sloping down towards the air enter-

ing side (Fig. 8). The rea-

 

 

son is simple. The steeper

 

45°

angle puts more water on

Entering

Leaving Air

the hot, dry, dirty side of

Air

the pad where it is needed

 

 

most. It also counteracts

 

15°

the tendency of the air to

 

Fig. 8

push the water toward the

 

 

 

back of the pad.

 

 

Cleaning pump. Cleaning the pump is necessary once a year at start- up. For your safety, disconnect from power source and unplug pump. Remove the pump from the mount bracket. Remove the base of the pump (Fig. 9). Clean the pump and turn the impeller to ensure free operation. Remove the pump spout and check for any blockage. After cleaning, reinstall the base onto

the pump. Reattach the pump to the mount in the cooler to ensure that the pump will not overturn. Do not forget to replace the spout and water delivery tube onto the

pump outlet. The pump has au-Impeller tomatic reset thermal protection.

Pump will operate normal again after obstruction is cleared.

Bleed off. Check bleed-off valve to be sure it is not clogged.

Winter Shut Down

Drain water. Always drain all of the water out of the cooler and water supply line when not in use for prolonged periods, and particularly at the end of the season. Keep the water line disconnected from both the unit and water supply so that it does not freeze.

Disconnect from power supply when not in use for extended periods of time.

Cover unit. To protect the life of the finish, a cover for the unit is suggested in extended periods of non use.

By following the operating, installation, and maintenance suggestions as outlined, you can get many years of efficient and satisfactory service from your cooler. In the event additional information is desired, your dealer will be more than glad to assist you in every possible way.

120 Volts

 

Pump Wiring Diagrams

240 Volts

 

 

 

 

 

 

Blue/Black

 

 

Blue/Black

 

 

White

 

 

White

 

 

Brown

 

 

Brown

 

 

Orange

 

 

Orange

 

 

Green

 

 

Green

 

 

Blue/Black

Pump

 

Blue/Black

 

 

White

Com.

To

White

 

 

Brown

 

Brown

Pump

To

 

Switch

Orange

 

Orange

Com.

 

 

Switch

Green

Ground

 

Green

Ground

 

 

= Wire Nut

 

 

= Wire Nut

 

 

110526

3

Page 3
Image 3
Essick Air SAD150 Maintenance, Pulley And Belt Adjustments, Spring Start-Up, Winter Shut Down, Volts, Pump Wiring Diagrams