Essick Air AS1C7112 Thermostat Operation, Wiring Diagrams 120 Volt, Automatic Operation Cool Mode

Models: AD1C71 AS2C7112 AS1C5112 AD2C71 AU1C7112 AD1C51 AD2C5112 AD2C51 AS2C5112 AS2C71 AU2C7112 AS1C7112 AD1C7112 AD2C7112 AS1C71 AS1C51

1 16
Download 16 pages 31.58 Kb
Page 3
Image 3
Thermostat Operation
CIRCULATING PUMP
RECEPTACLE
Fig. 6
Decrease
Amperage

Start cooler. Install both inspection panels, start pump, and allow to operate until pads are wet.

Check amperage. With pads wet and unit started, check amperage draw with an amperage meter.

Adjust pulley if necessary. If amperage draw is less than mo- tor rating, turn off electrical power and

remove inspection panels. Unplug mo-

tor inside cooler, this will protect you from someone turning on unit while

you are working inside. This should be done for your safety. Adjust pulley to a larger diameter and readjust belt tension, plug motor in, install inspection panels, and retest amperage draw. Repeat this

process until correct amperage draw is attained. Increasing motor pulley diameter increases amperage draw. Decreasing motor pulley diameter decreases amperage draw (see Fig. 6).

Automatic Operation (Cool Mode)CAUTION: Do not operate cooler with larger amperage draw than specified on motor plate.

Thermostat Operation

Automatic Operation (Cool Mode)

The fan and water pump are controlled automatically to achieve the desired comfort level.

This mode is activated by pressing the ‘Cool’ button. A blue LED is illuminated, and for a few seconds the LCD will display the ‘Set’ temperature. Pressing the ‘Cool’ button again deactivates this mode.

The Set temperature (the target temperature for control) may be altered by repeatedly pressing or holding the ‘Up’ and ‘Down’ buttons. The LCD will display ‘Set’ rather than ‘Room’ temperature for a short time after pressing the ‘Up’ or ‘Down’ button.

On starting, if the pads in the cooler are too dry, the fan may be delayed from starting until the pads have absorbed some water. This is called Pre-wet and lasts for 2 minutes, indicated by a flashing blue LED. Selecting ‘Fan’ and then ‘Cool’ will bypass the pre-wet and cause the fan and pump to start immediately. (If cooling is required).

During automatic operation, the control performs a 90 second water dump cycle every 8 or 12 hours of pump operation. This interval can be toggled between 8 or 12 hours by simultaneously holding the ‘Cool’ and ‘Fan’ buttons for 5 seconds. The selected interval is displayed for a short time. This action also starts a manual dump cycle.

Ventilation Operation (Fan Mode)

The fan speed is set by the user, the water pump is turned off.

This mode is activated by pressing the ‘Fan’ button. A green LED is illuminated, and the LCD indicates fan speed. Pressing the ‘Fan’ button again deselects this mode.

Pressing the ‘Up’ button selects maximum Fan speed, and ‘Hi’ is displayed in the LCD; pressing the ‘Down’ button selects minimum Fan speed, and ‘Lo’ is displayed in the LCD.

Time Delay Operation (Timer Mode)

Delayed start or finish in ‘Cool’ or ‘Fan’ mode.

The ‘Timer’ button is used to set a delay period of 2, 4 or 8 hours, depending on how many times the button is pressed.

If the cooler is operating in ‘Cool’ or ‘Fan’ modes when the ‘Timer’ button is pressed, the delay period determines when the cooler will switch off. If the cooler is Off when the ‘Timer’ button is pressed, the delay period determines when the cooler switches on.

The starting mode is indicated by a flashing LED. You can change this mode by pressing the appropriate button (‘Cool’ or ‘Fan’).

You can cancel the Timer function at any time by pressing the ‘Timer’ button until all the timer LED’s go out.

In The Event Of A Power Outage

If the cooler is operating in ‘Cool’ or ‘Fan’ mode when power is interrupted, the cooler will resume in the same mode of operation when the power is restored.

If the cooler was in any ‘Timer’ mode at the time of a power interruption, the cooler will remain off when power is restored.

Wiring Diagrams

120 Volt

240 Volt

COOLER TERMINAL BOX

BLACK

RED

WHITE

GREEN

ORANGE

FAN MOTOR

RECEPTACLE GREEN WHITE BLUE ORANGE Ventilation Operation (Fan Mode)Time Delay Operation (Timer Mode) BROWN In The Event Of A Power Outage

GREEN

WHITE

BLUE

ORANGE Wiring Diagrams240 Volt

BROWN

DRAIN PUMP

RECEPTACLE

TOGGLE SWITCH

SWITCH LEADS

 

GRAY

 

 

120 VAC

 

WHITE

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

GROUND

 

 

THERMOSTAT

 

FAN

PWR. SUPPLY

PUMP DUMP

BLACK

FCom FHi FLo

NLink N L1 LINK

DCom DP PCom PP

GRAY

 

 

 

 

 

RED

YELLOW

BLUE

VIOLET

WHITE

Manual background =WIRE NUT (11)

COOLER TERMINAL BOX

BLACK

RED

WHITE

GREEN

ORANGE

FAN MOTOR

RECEPTACLE GREEN WHITE Manual background BLUE Manual background ORANGE BROWN Manual background

CIRCULATING PUMP

RECEPTACLE GREEN

WHITE

BLUE

ORANGE

BROWN

DRAIN PUMP

RECEPTACLE

TOGGLE SWITCH

SWITCH LEADS

 

GRAY

 

 

240 VAC

 

WHITE

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

GROUND

 

 

THERMOSTAT

 

FAN

PWR. SUPPLY

PUMP DUMP

BLACK

FCom FHi FLo

NLink N L1 LINK

DCom DP PCom PP

GRAY

 

 

 

 

 

RED

YELLOW

BLUE

VIOLET

WHITE

Manual background =WIRE NUT (11)

110498-3

3

Page 3
Image 3
Essick Air AS1C7112, AS2C71, AS1C51 Thermostat Operation, Wiring Diagrams 120 Volt, Automatic Operation Cool Mode, 110498-3