Figure B

IMPORTANT FILLING INFORMATION

7)Fill by using a pitcher/container filled from your sink with cool tap water, or bottled distilled water. Do not use warm water as this might cause damage and leaking to the unit.

8)Fill the container by pressing the water fill door. It should pop up and open. Carefully pour the water into the reservoir. Fill up the tank to the fill line as shown on the fill line label.

9)When the tank is filled for the first time and the wick is still dry, it will take approximately 30 minutes for the wick to absorb the water from the reservoir. After this initial saturation, the tank should be refilled again to the fill line to obtain maximum running time.

10)If you only have softened water available in your home, you can use it, but you will notice a buildup of minerals on the wick much sooner. The tank holds 2.5 gallons. When filling, be

careful not to overfill.

AIR CLEANING FILTER (OPTIONAL)

11)The AirCare filter has four tangs that engage into four keyhole slots that mount the AirCare filter onto the outside of the back of the cabinet. (B)

NOTE: We recommend using Bemis by Essick Air Bacteriostat treatment part # 1970 when you refill the tank to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.

NOTE: Overfilling will result in water damage.

OPERATION

1)Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should be placed at least FOUR inches away from any walls and away from heat registers. Unrestricted airflow into the unit will result in the best efficiency and performance.

2)The digital control allows you to use the low setting for the quietest operation or a high setting for maximum output.

3)For initial operation, push the speed button once for the sleep setting and continuously press the button to increase desired speed to the highest speed. TO STOP the unit, press the button for two seconds, or keep pressing button until display reads OFF.

4)To take advantage of the digital humidistat, press the speed button to any setting other than OFF. Then adjust the set humidity by using the up and down buttons. Humidity will increase in increments of 5%. When the room humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically.

5)The refill light will indicate when the unit is completely out of water. The motor will also shut off. To refill, see Step 9. NOTE: When excessive condensation exists, a lower speed setting is recommended.

CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times.

OPTIONAL AIRCARE® FILTER

The first stage of the air filter is a high-efficiency, electrostatically charged filter media which traps dust, pollen, and airborne pollutants. The second stage is an activated carbon media which absorbs odors from cooking, pets, or tobacco smoke. We recommend replacing the AirCare® filter at least once a year and more often if necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the AirCare® filter. The certified water output of your humidifier will be reduced when using the AirCare® filter. AirCare® filters are optional and are not required for normal operation of the humidifier. AirCare® is registered trademark of Essick Air Products.

CARE AND MAINTENANCE

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and reservoir after cleaning.

We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home.

We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment reference part#1970.

1)Turn off unit completely and unplug from outlet.

2)Lift out the power pack.

3)Carry base to cleaning basin. Lift wick from the base allowing the water to drain. Rinse the wick under freshwater only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain.

REMOVING SCALE

4)Empty the water from the reservoir. Fill reservoir ½ full with water and add 8 oz. (1 cup) of undiluted vinegar. Let stand 20 minutes. Then empty solution.

5)Dampen a soft cloth with undiluted white vinegar and wipe out reservoir to remove scale. Rinse the reservoir thoroughly with fresh water to remove scale and cleaning solution before disinfecting.

3

Page 3
Image 3
Essick Air ED11910 manual Important Filling Information, AIR Cleaning Filter Optional, Operation, Optional Aircare Filter

ED11910 specifications

The Essick Air ED11910 evaporative humidifier is designed to enhance indoor air quality by adding moisture to dry environments, making it an ideal choice for homes particularly in arid climates. This model stands out for its combination of efficiency, user-friendly design, and advanced technology, making it a popular option among consumers seeking relief from dry air.

One of the standout features of the Essick Air ED11910 is its large water capacity, which allows for extended operation without frequent refills. With a tank capacity of 3.5 gallons, this humidifier can run continuously for up to 70 hours on a single fill, ensuring that your indoor air remains comfortable for days. This is especially beneficial for those who suffer from respiratory problems or dry skin due to lack of humidity.

The unit employs an advanced evaporative cooling system, which not only increases humidity levels but also cools the air as it evaporates. This process is energy-efficient, reducing electricity consumption compared to traditional humidifiers. The ED11910 utilizes a unique wick system that draws water from the tank and provides an even distribution of moisture throughout the room. The wick is also designed for easy replacement, which prolongs the unit’s lifespan and ensures optimal performance.

Noise can be a concern with many humidifiers, but the Essick Air ED11910 operates quietly. This makes it suitable for use in bedrooms or nurseries, allowing for a peaceful environment even during night-time operation. It features multiple fan settings, allowing users to adjust the level of humidity to their preference and room size effectively.

The design of the Essick Air ED11910 is both stylish and practical, featuring a sleek exterior that fits seamlessly into any home decor. The built-in hygrometer measures the room's humidity and automatically adjusts the fan speed to maintain the desired humidity level. Additionally, the unit has a filter indicator that informs users when it's time to replace the wick, ensuring the unit operates at maximum efficiency.

In summary, the Essick Air ED11910 is an excellent choice for anyone looking to improve their home’s humidity levels. With its large capacity, advanced evaporative technology, quiet operation, and user-friendly features, this humidifier offers a reliable and stylish solution for maintaining optimal indoor air quality.