Estate W10173755D Check Operation, Complete Connection, Electronic Ignition System

Models: W10173755D

1 32
Download 32 pages 58.68 Kb
Page 10
Image 10

Typical flexible connection

1.Use a combination wrench to attach the flexible connector to the adapters. Check that connector is not kinked.

A

 

B

 

D

C

 

E

F

 

G

H

 

A. Pressure regulator

E. Adapter

connection fitting

F. Use pipe joint compound.

B. Use pipe joint compound.

G. Manual shutoff valve

C. Adapter

H. 12" to 34" gas pipe

D. Flexible connector

 

5.Close the broiler door.

6.Place burners, burner caps and grates on the cooktop.

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

7.Plug into a grounded 3 prong outlet.

Complete Connection

1.Locate gas pressure regulator in the broiler.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

2.Check that the gas pressure regulator shutoff valve is in the

“ON” position.

Gas Pressure Regulator

Front View

Front

Side View

 

Shutoff valve

 

“ON” Position

3.Open the manual shutoff valve in the gas supply line. The valve is “open” when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

4.Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

Check Operation

Electronic Ignition System

Cooktop and oven burners use electronic igniters in place of standing pilots. When a cooktop control knob is turned to the “LITE” position, the system creates a spark to light the burner. This sparking continues until the control knob is turned to the desired setting.

When the oven control is turned to the desired setting, a hot surface igniter heats to a bright orange and ignites the gas. No sparking occurs. The glow bar remains on while the burner operates.

Check Operation of Cooktop Burners

1.If control panel and knobs were removed earlier, reinstall

knobs.

 

OFF

2. Push in and turn each surface

 

 

 

unit control knob to “LITE”

LITE

 

 

position. The flame should light

 

 

 

 

 

within 4 seconds.

 

 

LO

 

 

 

3. Turn control knob to “HI”

HI

 

 

 

 

 

position after burner lights.

 

 

 

4. Check each cooktop burner for

 

 

 

proper flame. The small inner

 

 

 

cone should have a very distinct

 

MED

blue flame 14" (0.64 cm) to 12" (1.3 cm)

 

 

outer

long. The outer cone is not as distinct

 

cone

 

 

as the inner cone.

 

 

 

5. Turn the control knob quickly to the “LO”

 

inner

position after the burner lights. If the

 

 

cone

 

 

 

flame goes out, turn the control knob to the “OFF” position.

6.Check each cooktop burner for proper low flame. The low flame should be a minimum, steady blue flame. The flame size should be 14" to 38" (0.64 cm to 0.95 cm) high.

10

Page 10
Image 10
Estate W10173755D Complete Connection, Electronic Ignition System, Check Operation of Cooktop Burners