Euphonix System 5 Installation Guide System 5 Components
68
GP132
Figure 3-29 GP132 Front and Rear Panels
NOTE: The maximum length for any MIDI cable is 10 m. Cables over this length may
cause data loss (this is the MIDI specification).
Input and Output Connections
Figure 3-30 GP132 Input and Output Connections
AC I
NPUT
100
V
TO
260
V
50
TO
60 H
Z
MIDI
RS422 NET O
UT
T
HRU
O
UT
T
HRU
I
N
I
N
O
I
S 1
S 1
S3
S3
S2
S2
GP132
RT1 1-8
RT1
RT2 9-16
RT2
RT3 17-24
RT3
RT4 25-32
RT4
GP132
1
Setup
Relays Only
Relays + Tallies
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
MIDI MMC N.O. C.C. SysX P2 EsBus EAddr Clear All
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Net NAddr 24T 32T 48T 64T 96T S / R T: pulse T: -ve R: pulse R: NC
INPUT
OUTPUT
INPUT PIN
COMMON PIN
10K
TLP620
OUTPUT PIN