HOW TO MAINTAIN (continued)
Check the
To Clean Pre-Motor Filter
1.Remove filter centered in the bottom of the dust cup compartment.
2.Shake filter to remove excess dust. If necessary, the filter can be cleaned by vacuuming with another cleaner or washing with mild detergent.
3.Reinstall filter after completely dry.
NOTE: If rubber gasket separates from motor adapter,
Use GENUINE EUREKA replacement
Motor | 1 | |
Adapter | ||
| ||
Gasket |
| |
| ||
Motor |
| |
Adapter |
|
3 |
HEPA Cartridge Filters (Only for models with HEPA | HEPA/Micron Filters in Filter Frame | |
cartridge.) | (Only for models with HEPA/Micron filter frame) | |
Check the HEPA filters with each disposable dust bag change. | ||
Check the HEPA/Micron filter with each disposable | ||
Replace twice a year or after every six bag changes. | ||
dust bag change. Replace twice a year or after every | ||
| ||
Latch | six bag changes. | |
| Filter Frame plus | |
Filter cartridge | filter (depending | |
on your vacuum | ||
(One complete unit) | model) | |
Tabs |
| |
To remove HEPA cartridge filters |
|
1. Push down latch and pull filter cassette back.
2. Then lift filter up and remove.
To replace HEPA cartridge filters
1.Place bottom tabs of filter cassette into slots.
2.Rotate filter toward cleaner.
3.Push upward on the latch to secure into place.
NOTE: To have the benefit of a sealed HEPA system, you must
use one of the HEPA cartridge filter systems.
Use GENUINE EUREKA replacement HEPA filter, 60285B.
14
To remove HEPA/Micron filters from filter frame
1.Push down latch and pull filter frame back.
2.Then lift filter up and out of filter frame.
To replace HEPA/Micron filters into filter frame
1.Place new filter in filter frame. Place bottom tabs of filter frame into slots.
2.Rotate filter frame toward cleaner.
3.Push upward on the latch to secure into place.
Use GENUINE EUREKA replacement filters, HEPA, part no. 61500; Micron, part no. 60801.