Eureka 4710 Series manual How to Maintain Your Vacuum Cleaner, Maintain Brush Roll

Models: 4710 Series

1 8
Download 8 pages 52.74 Kb
Page 6
Image 6
How to Maintain Your Vacuum Cleaner

How to Maintain Your Vacuum Cleaner

! Make sure vacuum cleaner is turned off and power cord is unplugged

Maintain Brush Roll

Motor can become hot with normal use.

Do not remove end caps. Remove hair and threads from brush roll periodically.

Check EXT-U Belt. Replace if worn, cut or out of shape.

! Avoid touching the motor shaft when checking brush roll or belt.
How to replace brush roll or belt

1) Use handle release to lower handle flat onto floor (Fig. 1).

2) Remove 2 screws from the front side of brush roll cover (Fig. 2).

3) Lift and remove brush roll cover (Fig. 3).

Fig. 1

Fig. 2

4)Remove brush roll and belt. Thread new belt around motor shaft and right end of brush roll (Fig. 4).

5)Pull right side of brush roll to stretch belt. Secure right end cap into base (Fig. 5). Align left end cap with square in base and push into place.

6)Rotate brush roll 2 turns to center belt.

7)Replace brush roll cover and 2 screws (Fig. 2).

8)Check belt view window to see if white dots on belt are moving. This indicates brush roll is turning (Fig. 6).

Fig. 3

Fig. 5

Fig. 4

Fig. 6

Change Light Bulb (on some models)

! Make sure vacuum is turned off and power cord is unplugged.

1)Remove 2 screws from lens cover (Fig. 7).

2)Remove lens cover and old bulb.

3)Push in new bulb (Fig.8). Make certain bulb will not touch lens cover.

4)Replace lens cover and 2 screws.

Fig. 7

Fig. 8

4Eureka Customer Service HELPLINE 1-800-282-2886