Euro-Pro EP366 manual Assembly, Troubleshooting Guide, Problem, Possible Reason, Possible Solution

Models: EP366

1 6
Download 6 pages 46.19 Kb
Page 5
Image 5
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

PROBLEM

 

POSSIBLE REASON

POSSIBLE SOLUTION

 

 

 

 

 

 

1.

Power cord not firmly

1.

Plug unit in firmly.

 

2.

Check fuse or breaker.

HAND VACUUM WILL

 

plugged into outlet.

 

 

Replace fuse/reset

NOT OPERATE

2.

No power in wall outlet.

 

 

breaker.

 

3.

Needs servicing.

 

 

3.

Call 1 (800) 798-7398.

 

 

 

 

 

 

 

 

 

 

 

1.

Empty dust cup filter –

 

 

 

 

(see page 4).

HAND VACUUM WILL

1.

Dust cup filter is full.

2.

Turn unit off and unplug

 

from wall outlet. Remove

NOT PICK-UP OR

2.

Unit clogged.

 

 

dust cup filter and check

SUCTION POWER IS

3.

Dust cup filter needs

 

 

for object(s) in air duct

WEAK

 

cleaning.

 

 

 

and remove.

 

 

 

 

 

 

 

3.

Clean or replace dust cup

 

 

 

 

filter. (see page 4).

 

 

 

 

 

DUST ESCAPING

1.

Dust cup filter is full.

1.

Empty dust cup filter.

2.

Dust cup filter is not

2.

Review dust cup filter

FROM HAND

 

installed correctly.

 

instructions. (see page 4)

VACUUM

3.

Puncture/hole in dust cup

3.

Replace dust cup filter.

 

 

filter.

 

(see page 4)

 

 

 

 

 

HAND VACUUM HOSE

 

 

1.

Remove hose and/or

1.

Hose clogged.

 

bushes. Remove

OR BRUSHES WILL

 

obstruction from hose.

2.

Dust cup filter is full.

 

NOT PICK-UP

2.

Empty and clean dust cup

 

 

 

 

 

 

filter.

 

 

 

 

 

ASSEMBLY

Warning: Always unplug from electrical outlet before opening the dust cup (container) (10).

Note: Dust cup filter (8) must be used when operating the hand vacuum.

1.To open the dust cup (container) (10), push button (1) and pull out the dust cup (10). Verify that the dust cup filter (8) is inside, then attach the dust cup (container) (10) to the hand vacuum.

2.To use the Hand Vacuum with the shoulder strap (5), attach it to the unit as shown below.

3.To attach the cleaning brush (6) or crevice brush (7) to the Hand Vacuum, push brush into the suction hole (3), as shown below.

4.To use the flexible hose (11), push the end of the hose into the suction hole (3), then attach the desired brush (6 or 7) to the other end of the flexible hose (11), as shown below.