present illumination. If the environment and the light source are changed, you need to adjust the white balance again.

ÖMANUAL: The manual adjustment mode enables a more precise adjustment. Please select ATW or AWC first. Then change to manual adjustment mode and press the SET button. Set the suitable color temperature, and increase or decrease the red and blue color values at the same time while checking the color changes of the object.

SETUP

 

 

WHITE BAL.

LENS

DC <┘

 

RED

+++++++++ 32

SHUTTER

___

> WHITE BAL.

MANUAL <┘

BLUE

+++++++++ 39

BACKLIGHT

OFF

 

 

AGC

MIDDLE

 

 

DNR

LOW

 

 

SENS-UP

AUTO <┘

 

 

SPECIAL <┘

 

 

 

EXIT

Note: Under the following conditions, the WHITE BALANCE function may not operate well. In such cases, please select the AWC mode.

1.When the object’s surroundings have a high color temperature.

2.When the object’s surroundings are dark.

3.If the camera faces a fluorescent light directly or is installed in a place where the illumination changes constantly, the WHITE BALANCE function may become unstable.

29

Page 29
Image 29
EverFocus EAN850A user manual Setup