10.Inspect the high flow filter system for any water leakage, tightening all connections as required until no leakage is observed. Turn on water and electrical power to all affected food service equipment. The filter system is now in service. Always keep a supply of replacement cartridges on hand.

SERVICE

No routine (daily, weekly, monthly, etc.) servicing of the pre-filter is required under normal operating conditions. The only scheduled servicing of the pre-filter is to change-out the cartridges whenever the water meter denotes a quantity of supply water (predetermined by the system requirements) has passed through the system.

CARTRIDGE CHANGE

Replace filter cartridges when they become excessively dirty, when the pressure gauge on the high flow filter system indicates extremely low pressure during water flow, or when changes in taste and odor are detected.

1.Turn off inlet and outlet water valves and press the red pressure relief valve on the filter cap.

2.Unscrew the sump from the filter cap using the sump wrench if necessary. Remove the used cartridge an empty the water from the sump.

The O-ring provides a water tight seal. Be sure the O-ring is properly seated and lubricated.

3.If the O-ring on the sump feels dry, lubricate it with a high grade silicone lubricant and reinstall in its groove in the sump.

4.Clean the sump with a mild solution of unscented dishwashing detergent. DO NOT use soap, strong or scented detergents, chemical cleansers or abrasives.

5.Position the replacement cartridge on the guide seat in the bottom of the sump. Then firmly screw the sump into the cap with the sump wrench. DO NOT USE A PIPE WRENCH.

SURGE TANK

STANDARD:

EV9336-50 EXTRA CAPACITY:

EV9336-51

INSTALLATION:

The surge tank must be installed on the effluent side of the high flow filter system. The surge tank has a 20±2 psi air charge WHEN EMPTY for proper performance. This must be checked before installation and re-charged if necessary. Refer to SERVICE.

It is important that the installation of the surge tank be clean and sanitary. All water-contact parts shall be immersed in chlorinated water (a capful of bleach per bucket of water) at the start of the installation procedure.

1.Shut off water and electrical power to all affected food service equipment.

2.Disconnect electrical power and water from the high flow filter system to be served by the Surge Tank. Close the inlet water ball valve on the high flow filter system and bleed water pressure from the system using the flushing valve on the high flow filter system.

The extra capacity (12 gallon) surge tank weighs 133 pounds and the standard (5 gallon) tank weighs 68 pounds when full. If the installation location in not on the floor, be certain its stand/shelf/platform is capable of safely supporting this weight.

3.Select a suitable location near the high flow filter system (not to exceed maximum of 10 feet) for the surge tank. The surge tanks overall dimensions are 1538" diameter x 3158" high for the extra capacity surge tank and 1538" diameter X 22" in height for the standard surge tank.

4.Disconnect the water line between the high flow filter system and the high flow, high volume fountain machine at the plated cross containing the activation valve.

NOTE: Be sure to use a high quality pipe joint compound or Teflon® tape on all threaded connections.

5.Install a 3/4" NPT x 1/2" NPT bushing into the the universal cross on the high flow filter system.

6.Install a 1/2" NPT tee into the bushing and orient as shown in figure 1.

7.Install a 1/2" NPT x 3/4" barb connector into the branch of the plated cross and a 1/2" NPT x 3/4" barb elbow into the run of the plated cross. Orient the elbow as shown in figure 1.

8.Reconnect a water line between the high flow filter system and the high flow, high volume fountain machine using appropriate connectors for the installation. One means is to slide a tube clamp onto the tubing (not provided) disconnected from the high flow filter system at the activation valve plated cross and install the tubing fully onto the newly installed 1/2" NPT x 3/4" barb elbow. Fully tighten the tubing clamp to secure the tubing onto the elbow barb.

9.Remove the protective cap from the nipple extending from the bottom of the extra capacity surge tank. For the standard capacity surge tank, remove styrofoam block, clean threads of styrofoam chips and remove plug from threaded, nipple fitting.

For standard surge tank, make sure plastic plug located in nipple threaded fitting is removed to insure proper installation of surge tank.

10.Install a ball valve onto the nipple and orient in any position convenient for operation of the handle. Install a 3/4" NPT x 3/4" barb connector into the ball valve.

11.With the surge tank at any convenient position near the high flow filter system, cut the tubing to length (maximum length 10ft.) and slide two tubing clamps onto the tubing. Install the tubing end fully onto the 3/4" NPT x 3/4" barb connector at the surge tank ball valve. Fully tighten one tubing clamp to secure the tubing onto the connector barb.

Disinfection of the surge tank is required prior to placing it into service.