Overall Dimensions:
30”H
Inlet and outlet connection: 3/8" OD tube connection
Wastewater line connection: 1/4" OD tube connection
Service Flow Rate:
Dependant on water pressure in storage tankand line size(s) to equipment
Pressure Requirements: Operating:
25 - 80 psi
Maximum Static:
100 psi (689 kPa),
Electrical connection required: 115 Volts AC, 60 Hertz, 1 Phase
Water Supply:
0.7 gpm (2.7l) min.
Inlet Temperature: 40°F - 100°F
Inlet TDS:
1,500 ppm max recommended
Operating Weight:
35 lbs. (not including storage tanks)
The contaminants or other substances removed or reduced by this system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
MRS Reverse Osmosis System
Configurable system that delivers reverse osmosis or
MRS 100/100CC/225/225CC system (excluding replaceable elements) is covered by a limited warranty against defects in material and workmanship for a period of one year after the date of purchase.