Operation
Figure7
1.Releasebutton2.Parkbrake
Theunitmustbetieddownandbrakeengagedwhen
transporting.

IgnitionSwitch

Locatedonrightconsole(seeFigure6).
Theignitionswitchisusedtostartandstopthe
engine.Theswitchhasthreepositions“OFF”,“ON”
and“START”.Insertkeyintoswitchandrotate
clockwisetothe“ON”position.Rotateclockwiseto
thenextpositiontoengagethestarter(keymustbe
heldagainstspringpressureinthisposition).Allow
thekeytoreturntothe“on”positionimmediately
aftertheenginestarts.
Figure8
1.Off3.Start
2.On
Note:Brakemustbeengaged,motioncontrol
leversout(neutrallockposition)andPTOswitch
disengagedtostartengine.(Itisnotnecessaryforthe
operatortobeintheseattostarttheengine.)

HourMeter

Locatedontherightconsoleinthemessagedisplay
(seeFigure6andFigure9).
Thehourmeterrecordsthenumberofhoursthat
theenginehasrun.
Figure9
1.LCDIndicators
2.Lowfuelindicatorlight
3.Fuellevelbardisplay
4.Lowvoltageindicatorlight
5.Hour/Voltagedisplay
Thehourmeterisrecordingwhenthedecimalpoint
isashinginHour/Voltagedisplay.
Hoursaredisplayedwhenthekeyisofforwhenthe
machineisrunning.
Note:Iftheignitionkeyisturnedtothe“ON”
positionforafewsecondsbeforecrankingthe
engine,thebatteryvoltagewilldisplayinthearea
wherethehoursarenormallydisplayed.
Note:TheLCDindicatorsappearwheneach
controlmeetsthe“safetostart”mode(e.g.the
indicatorturnsonwhentheoperatorisintheseat.)

FuelShut-OffValve

Locatedbehindandbelowtheseat.
Thefuelshut-offvalveisusedtoshutoffthefuel
whenthemachinewillnotbeusedforafewdays,
duringtransporttoandfromthejobsite,andwhen
parkedinsideabuilding.
Alignvalvehandlewiththefuellinetoopen.Rotate
90°toclose.

FuelGauge

Locatedontherightconsoleinthemessagedisplay
(seeFigure6andFigure9).
Thefuellevelisshownonabardisplay.Theindicator
lightappearswhenthefuellevelislow(approximately
onegallonremaininginthetank).
20