Extron electronic 3G-AE 100 manual Analog Output Connector Wiring, 3G-AE100 Panels and Cabling

Models: 3G-AE 100

1 13
Download 13 pages 12.49 Kb
Page 9
Image 9
Figure 4. Analog Output Connector Wiring

CLoop Through connector — If necessary, plug in an output device to the

Loop Through connector. The SDI input signal is equalized, re-clocked, and routed to the Loop Through connector. This connector may also be used for cascading to another 3G-AE 100.

NOTE: It is not required to connect a device to the Loop Through connector in order to extract audio from the input device.

DAnalog Outputs — Connect up to four audio output devices to the Analog Outputs, using a cable with a balanced or unbalanced 3.5 mm, 5-pole captive screw connector. Wire as shown below.

 

Tip

 

Ring

 

Sleeves

Do not tin the wires!

Tip

 

Ring

 

No Ground Here

L

Tip

 

 

Sleeves

 

Tip

R

No Ground Here

L R

Balanced Audio Output

Unbalanced Audio Output

Figure 4. Analog Output Connector Wiring

ATTENTION: Connect the sleeve to the ground (Gnd) terminal. Connecting the sleeve to a negative (-) terminal will damage the audio output circuits.

EGroup Select DIP switch — see the Operation section on the next page for instructions on using the Group Select DIP switch.

3G-AE 100 • Panels and Cabling

4

Page 9
Image 9
Extron electronic 3G-AE 100 manual Analog Output Connector Wiring, 3G-AE100 Panels and Cabling