Testing the System

The TeamWork system has been pre-configured so that, once all the connections have been made and the devices are all powered on, there should be no need of further configuration for the system to work. To ensure that the system has been set up correctly, follow these steps:

1.Power on the equipment

zz Source devices zz Switcher

zz System controller (IPL T PC1)

2.Press the power button (A) on the front panel of the system controller. The LED (B) lights green when power is being supplied to the attached output device.

3.Turn on the display and confirm that the display is receiving power.

4.Go to the menu for the display and disable the Sleep Mode feature. If necessary, see the display user guide.

5.Press the power button on the power controller. The LED should go out and the display should be turned off.

6.Connect one of the “Show Me” cables to a video source, such as a laptop.

1

IPL T PC1

POWER

 

 

R

 

 

100

TX

INPUT

LINK

 

 

RX

IR

ACT

2

7.Press the “Show Me” button on that cable. If the source device is providing a video signal, the LED on the Show Me cable lights blue and the display automatically turns on.

8.Connect a second “Show Me” cable to a second video source.

9.Repeat step 7 to verify that the second source device is providing a video signal and it is the output signal from the switcher.

When the button on the second “Show Me” cable is pressed, the LED lights blue and the LED on the first cable is switched off.

10.Disconnect all the “Show Me” cables from the source devices.

After about 30 seconds without an input signal, the display should turn off.

11.Connect a “Show Me” cable to a source device and press the “Show Me” button on that cable. As soon as an active video signal is detected, the display should automatically turn on.

Troubleshooting

No Image on the Display:

Cause 1 — There is a problem with the source device:

Solution — Verify the source device is powered on and outputs an active signal. Cause 2 — Cable connections are incorrect:

Solution — Verify the HDMI output cable from the switcher is connected to the current HDMI input of the display. Cause 3 — Display is off:

Solution 1 — Verify the display is in the on state.

Solution 2 — The TeamWork system turns the display on and off by controlling the AC power. If the display has a Sleep Mode feature, this feature must be disabled to prevent the display from accidentally powering off.

Cause 4 — The display has a problem:

Solution — Verify that the display functions correctly.

Cause 5 — The display cannot show video at the incoming resolution:

Solution — The EDID settings on the switcher may need to be changed. Refer to the SW HDMI Series User Guide (see

www.extron.com) or contact an Extron Support representative at www.extron.com/company/contactus.aspx.

11

Page 11
Image 11
Extron electronic 600 manual Testing the System, Troubleshooting, No Image on the Display

600 specifications

Extron Electronics is a well-respected name in the audiovisual industry, providing a range of sophisticated solutions to meet the needs of various installations. Among its notable offerings is the Extron 600 series, a line of products designed to elevate the performance and functionality of AV systems.

The Extron 600 series includes various devices primarily focused on video processing and scaling. One of the standout features of this series is its ability to handle multiple video formats. It supports high-definition resolutions, ensuring compatibility with a wide range of source devices and displays. This flexibility allows users to connect various equipment without worrying about format discrepancies.

Another prominent characteristic of the Extron 600 is its advanced scaling technology. The products in this series feature powerful DEEP COLOR support and exceptional image quality, providing sharp, vibrant outputs that enhance the overall viewing experience. The intelligent scaling algorithms automatically adjust content, maintaining visual integrity across different resolutions, which is crucial for professional presentations and high-stakes environments.

Connectivity options are abundant in the Extron 600 series. The devices often include HDMI, DisplayPort, and analog inputs, enabling seamless integration with diverse AV setups and ensuring that users can connect their preferred devices without hassle. Additionally, many units are equipped with built-in audio features, allowing for streamlined AV distribution while reducing the need for extra hardware.

The Extron 600 also boasts user-friendly controls. With intuitive interfaces and programmable presets, setup and operation are simplified, making it easy for users to manage their AV environments effectively. Remote management capabilities are often included as well, allowing for easy monitoring and adjustments through a centralized system.

Durability is a key characteristic of the Extron 600 series, built with high-quality components that withstand the rigors of continual use in commercial environments. Extron backs its products with robust support and warranty options, assuring users of reliable performance.

Overall, the Extron 600 series exemplifies cutting-edge technology, exceptional versatility, and user-centric design, making it an excellent choice for any professional AV application. With its combination of advanced features and reliable operation, it stands out as a significant contribution to modern audiovisual systems.