AVTracConnectivity Box Installation Guide

Before installation of the AVTrac connectivity box, the base track must already

 

be installed. For full information about AVTrac installation, consult the

 

AVTrac Installation Guide. Install the connectivity box as follows:

Cover

End Plate

 

1. Remove the cover panel and end plates from the

 

connectivity box. One end has three mounting holes

3 Mounting Holes

in the base, the other has two. The end with three

 

holes faces toward the wall. Align the end with

2 Mounting Holes

two mounting holes with the end of the base

 

track.

End Plate

2. Mark where the holes in the bottom of the connectivity box lie over the base track and,

using a 1/4" metal bit (not provided), drill at least three holes through the track.

3. Using the provided masonry bit, drill 5/32" diameter by 1 1/2" deep pilot holes into the concrete through the predrilled holes in the track.

4. Reposition the connectivity box, in the correct orientation, over the

track (the end of the box with three holes must face back toward the wall). Using at least three of the provided 3/16" masonry screws, secure the box to the track and floor.

5.Populate the lid of the box with the required Architectural Adapter Plates and AC power modules. Run cabling as necessary, and reattach the end plates and cover panel.

AVTracPower Module Installation Guide

Before installation of the AVTrac Power Module, the AVTrac base track and connectivity box must already be installed. For full information about AVTrac installation, consult the AVTrac Installation Guide. Install the AC module as follows:

To Main Circuit

CAll electrical installation should be

 

performed by qualified personnel in

 

accordance with local and national

Conduit

electrical codes.

 

US

Tabs

AC Power

 

Module

 

WSwitch off all electrical power before connecting

Junction Box

the AC conduit to a junction box, and keep power

Studs

off until installation is complete.

 

1.

White or Blue (neutral)

Black or Brown (hot)

2.

Green

or Green/Yellow

(ground)

Install the power module at the end of the connectivity

Slots

 

box that is closest to the wall. Slide the side tabs into the slots on the side of the connectivity box and mount the power module on the stud(s) in the floor of the box (see the figure above right). Secure the module to the stud(s) by hand tightening the provided 6/32" nut(s).

Run the unattached end of the conduit and connect it to a convenient junction or circuit box (see the figure at left). Extron recommends that the junction box be directly wired to the main circuit.

AC Conduit or Cable

From AVTrac AC Power Module

CThe module does not have a fuse and is rated at 15 A, maximum, for US modules and 10 A, maximum, for international modules.

Extron USA - West

 

Extron USA - East

 

Extron Europe

 

Extron Asia

 

Extron Japan

 

Extron China

 

Extron Middle East

68-1617-01

 

 

 

 

 

 

Headquarters

 

+800.633.9876

 

+800.3987.6673

 

+800.7339.8766

 

+81.3.3511.7655

 

+400.883.1568

 

+971.4.2991800

Rev B

 

 

 

 

 

 

 

+800.633.9876

 

Inside USA / Canada Only

 

Inside Europe Only

 

Inside Asia Only

 

+81.3.3511.7656 FAX

 

Inside China Only

 

+971.4.2991880 FAX

11 08

Inside USA / Canada Only

 

+1.919.863.1794

 

+31.33.453.4040

 

+65.6383.4400

 

 

 

+86.21.3760.1568

 

 

 

 

 

 

 

 

 

 

 

 

 

+1.714.491.1500

 

+1.919.863.1797 FAX

 

+31.33.453.4050 FAX

 

+65.6383.4664 FAX

 

 

 

+86.21.3760.1566 FAX

 

 

 

+1.714.491.1517 FAX

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Extron electronic manual AVTrac Connectivity Box Installation Guide, AVTrac Power Module Installation Guide, 68-1617-01