Dante Network Audio Setup

The following is the recommended procedure for configuring DMP 128 AT models on a Dante network.

NOTE: A connection to both the Dante (AT) Ethernet switch and the DMP 128 LAN port is required to follow this setup procedure. If the control computer has only one Ethernet port, connect it to a rear panel AT port (item J on page 2). Then connect a short CAT 5 cable from the LAN port (item Ç on page 2) to an unused AT port (item J on page 2). Alternately use an Ethernet switch to connect the control computer to both the LAN and AT ports.

1.Connect the control computer to an AT (Dante) port on the DMP 128. Also connect the control computer to the DMP 128 LAN port (see Note above).

2.Start DSP Configurator in Live mode (see steps 1, 2, and 3b of DMP 128 Configuration on the previous page).

3.From the DSP Configurator toolbar, select Tools>Device Settings.

4. In the Unit Name: field,

enter a descriptive name for the DMP 128 (typically the device name and location) that enables it to

be easily identified on the

network.

5.Click Apply, then close the dialog box.

6.From the DSP Configurator toolbar, select Network Audio Control. If Dante Controller does not launch, see the Dante Controller Software Installation (AT models only) section on the previous page.

7.From Dante Controller toolbar, select Device>Device View.

8.Choose the Dante device. The DMP 128 appears as DMP128, plus the last six digits of the Dante MAC address.

NOTE: Connect DMP 128 units to the Dante network one at a time to easily identify the units. To confirm the proper device is configured, compare the Dante MAC address printed on the rear of the unit with the MAC address in the Device View.

9.Select the Device Config tab in Dante Controller.

10.Rename the device to match the DSP 128 name given in DSP Configurator (see step 4 above), then press <Enter>.

11.Select Yes to confirm the new name.

12.To connect additional DMP 128 units, repeat this procedure with the next device.

See the Dante Controller section in the DMP 128 User Guide for operation of the controller software.

Telephone Ports (DMP 128 C P and DMP 128 C P AT only)

The DMP 128 provides a telephone interface with separate input and output signal processing paths (labeled “Telephone Rx” and “Telephone Tx” on the DSP Configurator main screen on the previous page). The country code must be entered before attaching the DMP 128 to a phone system.

To set or change the country code of a phone model:

1.Follow Steps 1 and 2 from To Configure the DMP 128 on the previous page, then select Live in the Mode box.

NOTE: The device settings dialog can be accessed only in Live mode.

2.From the main DSP Configurator menu , select Tools>Device Settings.

3.From the Device Settings dialog, select the Phone Settings tab (see diagram at right).

4.If the correct country code is not listed under Selected Country:, click Change Phone’s Country Code, then select the correct country code for your region from the dropdown list.

5.Click Apply, then close the dialog box.

See the DMP 128 User Guide for operating details of the phone modem.

Extron Headquarters

 

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

Extron Korea

Extron India

+800.633.9876 Inside USA/Canada Only

+800.3987.6673

+65.6383.4400

+81.3.3511.7655

+86.21.3760.1568

+971.4.299.1800

+82.2.3444.1571

1800.3070.3777

 

 

Inside Europe Only

+65.6383.4664 FAX

+81.3.3511.7656 FAX

+86.21.3760.1566 FAX

+971.4.299.1880 FAX

+82.2.3444.1575 FAX

(Inside India Only)

Extron USA - West

Extron USA - East

 

 

 

 

 

 

 

+1.714.491.1500

+1.919.850.1000

+31.33.453.4040

 

 

 

 

 

+91.80.3055.3777

+1.714.491.1517 FAX

+1.919.850.1001 FAX

+31.33.453.4050 FAX

 

 

 

 

 

+91.80.3055.3737 FAX

 

 

 

 

 

 

 

 

 

4

© 2013 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com

68-2036-50

 

 

Rev. C 10 13

 

 

Page 4
Image 4
Extron electronic DMP128 Dante Network Audio Setup, Telephone Ports DMP 128 C P and DMP 128 C P AT only