Mounting Accessories

Mounting Accessories

Mounting kit

Part Number

 

 

 

 

RSF 123 3.5-inch deep 1U rack shelf kit (transmitter only)

60-190-20

 

 

RSB 123 3.5-inch deep 1U rack shelf (transmitter only)

60-604-21

 

 

RSU 126 6-inch deep 1U universal rack shelf kit

60-190-10

 

 

RSB 126 6-inch deep 1U basic rack shelf

60-604-11

 

 

RSU 129 9.5-inch deep 1U universal rack shelf kit

60-190-01

 

 

RSB 129 9.5-inch deep 1U basic rack shelf

60-604-02

 

 

MBU 125 under-desk mount kit

70-077-01

 

 

MBD 129 through-desk mount kit

70-077-02

 

 

PMK 350 low profile projector mount kit, white

70-563-03

 

 

Mounting the Transmitter or Receiver

Tabletop Use CAUTION: Installation and service must be performed by authorized personnel only.

The 1-inch high, quarter rack width DTP DVI 301 transmitter or receiver can be placed on a table, mounted in a rack, or mounted under a desk or table. The receiver can also be mounted on a projector bracket.

Tabletop Use

Affix the included rubber feet to the bottom of the unit and place it in any convenient location.

Mounting kits

Mount the unit using any of the mounting kits listed above, in accordance with the directions included with the kit.

UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) requirements pertain to the installation of the unit into a rack.

1.Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified by Extron.

2.Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

3.Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

4.Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (such as use of power strips).

DTP HDMI 301 • Reference Information 16

Page 22
Image 22