DVI DL 101 • Installation and Opeation
Installation and Operation, cont’d

2-8

DVI DL 101 • Installation and Opeation

2-9

6. Secure the bracket to the U-bolt with the included hex
nuts, washers, and lock washers. Tighten the hex nuts just
enough that they can be loosened by hand.
PMK 350 mounting
Mount the DVI DL to a PMK 350 bracket as follows:
1. Remove the front and rear plates from the PMK 350, using
an Extron Tweeker or a #2 Philips screwdriver. Retain the
screws to reattach the plates when you are nished.
2. If necessary, remove the feet from the bottom of the unit.
3. Secure the DVI DL to one side of the mounting tray,
using two of the supplied 4-40 x 3/16” screws in opposite
(diagonal) corners.
Extron
PMK 350
Multi-product Projector
Mounting Kit
Cover Sheet
Front Plate
Rear Plate
U-bolt
L-shaped
Bracket
Contoured
Base
Extron
Power Supply
Extron
DVI DL 101
Equalizer

PMK 350 projector mounting a DVI DL

4. Using the two included tie wraps, strap the power supply
to the PMK bracket.
5. If desired, remove the back panel of the PMK 350 and
mount additional device(s) at the back of the bracket, as
described in step 3.
6. Place the PMK 350 around the projector ceiling mounting
pole.
U-bolt
Extron
PMK 300
Multi-product Projector
Mount Kit
Contoured
Bracket
Base
Extron
DVI DL 101
Equalizer
Power Supply

Mounting with the projector pole on the inside

4. Place the contoured bracket brace against the pole and
opposite the back plate. The pole should t snugly into the
depression in the center of the bracket brace.
5. Place the U-bolt around the ceiling pole. Insert the
two legs of the U-bolt through the round holes on the
contoured bracket brace and then through the slotted holes
on the bracket’s mounting plate.
N The supplied U-bolt fits a typical (1.5" to 2.0" diameter)
ceiling pole.