Under-furniture mounting

Installation, cont’d

Under-furniture mounting

The GLI 350xi or ADA 2/GLI 350xi can be mounted under furniture, such as a desk or table, using the optional MBU 125 mounting kit (Extron part #70-077-01), as follows.

1.

If rubber feet were previously installed on the bottom of

 

the unit, remove them.

2.

Attach the mounting brackets to the GLI with the provided

 

machine screws.

Under-furniture mounting of the GLI

3.

Hold the unit with the brackets attached against the

 

underside of the table or other furniture. Mark the location

 

of the screw holes of the bracket on the mounting surface.

4.

Drill four pilot holes, each 3/32" (2 mm) in diameter by

 

1/4" deep (6.3 mm) in the mounting surface at the marked

 

screw locations.

5.

Insert #8 wood screws into the four pilot holes. Tighten

 

each screw into the mounting surface until just less than

 

1/4" (6.3 mm) of the screw head protrudes.

6.

Align the mounting screws with the slots in the brackets

 

and place the unit against the surface, with the screws

 

through the bracket slots.

7.

Slide the unit slightly forward or back, then tighten all four

 

screws to secure the unit in place.