Installation

Application Example

The following illustration is an application example for the GLI 350xi.

Extron

GLI 350xi

Ground Loop

Isolator

Projector

GLI

 

350

xiS

GROUNDLO

OP ISOERIES

 

LATOR

Mounting the GLI 350xi and ADA 2/GLI 350xi

The GLI 350xi and ADA 2/GLI 350xi ground loop isolators can be set on a table, mounted on a rack shelf, or mounted under a desk or other furniture.

NInstall the GLI near the display device(s) rather than near the source device. See the previous application example illustration.

Tabletop use

Four self-adhesive rubber feet are included with the ground loop isolator.

For tabletop use, attach one foot at each corner of the bottom side of the unit and place the unit in the desired location.

Extron

RGB 109xi

Interface

Front

INPUT

 

MBUOF

RE

 

NFEITORDLO

 

 

OUTCPAULT

H.

SHIFT

VGAIN

RGB1

TER

FACE W

09xi

 

 

/ADSP

Rear

SPARE

SERR

DDSP

SOGOUT

UL rack mounting requirements

The following Underwriters Laboratories (UL) requirements pertain to the safe installation of the equipment in a rack.

1.

Elevated operating ambient temperature — If the unit

 

is installed in a closed or multi-unit rack assembly, the

 

operating ambient temperature of the rack environment

 

may be greater than room ambient temperature.

 

Therefore, install the equipment in an environment

 

compatible with the maximum ambient temperature

 

(Tma = +104 °F, +40 °C) specified by Extron.

Local Monitor

PC

GLI 350xi application example

2.

Reduced air flow — Install the equipment in a rack so that

 

the amount of air flow required for safe operation of the

 

equipment is not compromised.

3.

Mechanical loading — Mount the equipment in the rack so

 

that a hazardous condition is not achieved due to uneven

 

mechanical loading.

4.

Circuit overloading — Connect the equipment to

 

the supply circuit and consider the effect that circuit

 

overloading might have on overcurrent protection and

 

supply wiring. Appropriate consideration of equipment

 

nameplate ratings should be used when addressing this

 

concern.

5.

Reliable earthing (grounding) — Maintain reliable

 

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips).

2-2

GLI 350xi & ADA 2/GLI 350xi • Installation

GLI 350xi & ADA 2/GLI 350xi • Installation

2-3