Quick Start Guide — IPL M PDP-ES

This Quick Start will briefly walk you through the installation and initial operation of the IPL M PDP-ES card in conjunction with your Pioneer plasma. For more detailed instructions, please refer to the IPL M PDP-ES User’s Manual.

Installation of the IPL M PDP-ES

Quick Start Guide — IPL M PDP-ES, cont’d

 

Quick Start Guide — IPL M PDP-ES, cont’d

Removing the Pioneer communication ES card

Before installing the Extron IPL M PDP-ES interface card, the Pioneer communication ES card shipped within the plasma must be removed. The communication ES card is found in the communication ES card slot of the connection panel, as shown in the plasma below.

Pioneer Plasma Display

Connection Panel

Pioneer ES Card Slot (communication)

Figure 1 — Pioneer ES Card Slots

To remove the Pioneer communication ES card, do the following:

1.

Ensure that the Pioneer plasma is turned off and

 

disconnected from the power source.

2.

If the plasma display is laid with its screen side facing

 

down, ensure that it is on a flat surface with a blanket or

 

other soft material underneath.

 

 

Never rest the plasma in such a way that weight or pressure

CAUTION

 

 

 

 

is placed on the screen surface.

3.

If the plasma display stand obscures the communication ES

 

card slot, remove or slide the stand away from the working

 

area.

 

4.Remove the two side screws keeping the Pioneer communication ES card in place, and gently pull the center knob to remove the card.

Gently pull the center knob

Figure 2 — Removing the Pioneer ES card

Installing the Extron IPL M PDP-ES card

To install the Extron IPL M PDP-ES interface card, do the following:

1.Insert the IPL M PDP-ES gently and evenly in alignment with the two rails visible inside the ES card slot. Press on the center of the card faceplate to push the card securely into the slot.

Push gently

Figure 3 — Inserting the IPL M PDP-ES card into the communication slot

CAUTION

Be very careful when inserting the card. Do not use excessive

 

force, and push the card in as straight as possible; a crooked

 

entry could damage the card or the plasma.

2.When the card is seated securely in the slot, use the spring loaded thumb screws on either end of the card faceplate to secure the card in place.

Thumb screws

Figure 4 — Securing the IPL M PDP-ES

3.Affix the Extron IPL M PDP-ES sticker label over the existing Pioneer label, as shown on the following page.

Insure that the sticker is placed flush over the Pioneer label.

Figure 5 — The IPL M PDP-ES sticker label

Establishing a Hardware Connection Through the Ethernet/LAN Port

This type of connection is used to connect the IPL M PDP-ES interface card to a LAN for remote control of the Pioneer plasma and other connected devices.

1.Plug one end of a Cat 5, straight-through Ethernet cable into the LAN port of the IPL M PDP-ES interface card.

2.Plug the other end of the Ethernet cable into a network switch, hub, or router connected to an Ethernet LAN or to the Internet.

3.Ensure that your PC is connected to the network switch, hub, or router.

Configuring the IPL M PDP-ES Using the ARP Command

Both your computer and the IPL M PDP-ES interface card must be connected to the same LAN. Also, ensure that your PC is on the same subnet mask as the IPL M PDP-ES card. Use ARP to configure the IP address as follows:

1.Obtain a valid IP address for your IPL M PDP-ES card from your network administrator.

2.Obtain the IPL M PDP-ES card’s MAC address (UID #) from the label on its face panel.

3.Access the MS-DOS command prompt, then execute the ‘arp –s’ command.

Enter the desired new IP address and the MAC address (on the face panel) for the interface card. For example:

arp –s 10.13.170.15 00-05-A6-00-0A-90

4.Execute a ‘ping’ command by typing your new IP address at the command prompt. For example:

ping 10.13.170.15

1

IPL M PDP-ES • Quick Start

IPL M PDP-ES • Quick Start

2

IPL M PDP-ES • Quick Start

3

Page 2
Image 2
Extron electronic quick start Quick Start Guide IPL M PDP-ES, Configuring the IPL M PDP-ES Using the ARP Command

IPL M PDP-ES specifications

Extron Electronics is renowned for its innovative AV solutions, and the IPL M PDP-ES is a standout product that exemplifies the company's commitment to performance and versatility. The IPL M PDP-ES is a professional-grade power distribution unit designed for use with flat panel displays and other AV equipment. It seamlessly integrates with Extron’s extensive line of control systems, offering an array of features that enhance usability and efficiency in various environments.

One of the main features of the IPL M PDP-ES is its ability to provide power management for multiple displays, facilitating centralized control. This device includes a built-in Ethernet port, which allows for network connectivity and remote monitoring. Users can conveniently manage power settings, receive status notifications, and even configure the device through an intuitive web-based interface from any location within the network.

The IPL M PDP-ES also boasts advanced surge protection and power conditioning technology, ensuring that connected equipment is safeguarded against voltage spikes and electrical noise. This is crucial in maintaining the longevity and reliability of AV systems, especially in environments prone to unstable power conditions. Another notable characteristic is its reliable, high-capacity relay outputs that support the on/off operation of powered devices, providing versatility in system design.

In terms of physical design, the IPL M PDP-ES features a compact 1U rack-mountable form factor, making it suitable for installation in equipment racks or AV carts. The device's robust construction and high-quality components contribute to its durability, ensuring it can withstand the demands of a professional AV environment.

Furthermore, customizable features allow for tailoring to specific user needs. The IPL M PDP-ES supports Extron’s GlobalViewer® Enterprise, providing a comprehensive AV management solution that allows system administrators to monitor and control AV devices throughout a facility.

In summary, Extron’s IPL M PDP-ES is a powerful and versatile power distribution unit that combines advanced technology with ease of use. Its features, including network connectivity, surge protection, and a compact design, make it an essential component for any AV system, enhancing both performance and reliability in diverse applications. With the IPL M PDP-ES, users can enjoy a streamlined approach to managing their AV equipment, ensuring effective operation and peace of mind.