4-16 IPL T S Series • Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Directories

 

 

 

 

 

 

 

 

Change/create a

Epath/directory/CJ}

Wpath/directory/CJ

Dir•path/directory/]

The directory’s name must be composed

directory

 

 

 

of alphanumeric characters and may

 

 

 

 

include the minus sign (hyphen, -) and the

 

 

 

 

colon (:). The first character must be a letter.

 

 

 

 

Case does not matter. No blank or space

 

 

 

 

characters are permitted in the name.

 

 

 

 

Include the full path, not just the name of

 

 

 

 

the directory.

 

 

 

 

 

 

 

 

 

Nonalphanumeric characters

 

 

 

 

in the path (for example, /) must be

 

 

 

 

encoded to hex. characters for use with a

 

 

 

 

Web browser.

N A directory does not fully exist until a file has been copied into that path. Also, the IPL T S unit operates differently from PC operating systems: files stored in and directories created

in the IPL T S device may have the same names.

 

 

 

Example:

Emajordirectory/subdirectory/next-level/CJ}

 

 

 

 

Wmajordirectory %2F subdirectory %2F next-level %2F CJ

 

 

 

 

Dir•majordirectory/subdirectory/next-level/]

 

 

 

 

In this case, the path is majordirectory/

 

 

 

 

subdirectory/. The directory that was just

 

 

 

 

created or changed to is called next-level.

Example:

Ecustompages/HTMLfiles/CJ}

 

 

 

 

Wcustompages%2F HTMLfiles%2FCJ

This example just created a subdirectory for

 

 

 

Dir•custompages

storing the user’s custom-made HTML files.

 

 

 

HTMLfiles/]

The directory that was just created is called

 

 

 

 

HTMLfiles.

Example:

Eoak/CJ}

Woak %2FCJ

Dir• oak]

 

Back to root directory

E/CJ}

W%2FCJ

Dir•/]

 

Up one directory

E..CJ}

W52E%2ECJ

Dir•path/directory/]

 

View current

ECJ

WCJ

path/directory/]

 

directory

 

 

 

 

NThe current directory is determined on a per-connection basis. At the beginning of each IP connection/session, the current directory is selected as the root directory.

Erase user-supplied

EfilenameEF}

WfilenameEF

Del•filename]

Web page/file24 28

 

 

 

 

 

 

 

Erase current

E/EF}

W/EF

Ddl]

directory and its files

 

 

 

24 28

 

 

 

Communication and Control, cont’d

Page 56
Image 56
Extron electronic IPL T S manual Directories, Ecj Wcj

IPL T S specifications

The Extron Electronics IPL T S is a powerful tool designed for seamless integration and control in AV applications. It provides a complete AV control solution that is highly intuitive and customizable. With its diverse set of features, the IPL T S caters to various environments, from educational institutions to corporate settings, delivering functionality and flexibility.

One of the standout features of the IPL T S is its user-friendly interface, which allows users to easily navigate through different control options. The device supports customizable touchscreen control, enabling users to personalize layouts according to their specific needs. This adaptability not only enhances user experience but also increases efficiency during presentations or meetings.

The technology behind the IPL T S includes advanced network control capabilities. It utilizes Extron’s well-rounded Global Viewer® technology, allowing users to manage and monitor their AV systems through a web-based application. This feature is crucial for IT managers or AV administrators who need real-time insight into the performance and status of their equipment, ensuring seamless operation.

Connectivity is another critical aspect of the IPL T S. It supports various control protocols, including IP, RS-232, and USB, making it compatible with a wide range of third-party devices. This compatibility not only simplifies integration but also offers users the flexibility to expand their AV systems as needed.

Moreover, the IPL T S is designed with robust security features, ensuring that control systems remain secure from unauthorized access. This is particularly important in corporate environments where sensitive information may be presented during meetings.

The device is built with reliability in mind, featuring Extron’s renowned quality assurance processes. It’s designed for uninterrupted performance, ensuring that users can rely on it during critical situations. Additionally, the IPL T S is backed by Extron’s extensive technical support, providing users with peace of mind.

In summary, the Extron IPL T S is an advanced, versatile AV control solution that greatly enhances the user experience in various settings. With its intuitive interface, extensive connectivity options, robust security features, and reliable performance, it stands out as an essential tool for modern AV applications, streamlining control and enabling effective communication.