Image 57

IPL T S Series • Communication and Control 4-17

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

Erase current

E//EF}

W//EF

Ddl]

 

directory and

 

 

 

 

subdirectories 24 28

 

 

 

 

 

 

 

 

 

List files from current

EDF}

WDF

 

 

directory

 

 

 

 

Get connection listing

ECC }

WCC

[number of connections]]

 

 

 

 

or Icc [total number of client

 

 

 

 

connections]]

 

Example:

ECC }

WCC

002]

The example shows two client connections.

Stream files via Telnet or RS-232

NFile streaming commands should be used by advanced programmers only.

Load file to user flash E+UF filesize, filename}

{raw, unprocessed data in a file of Upl]

memory24, 28

up to filesize}

NIf the IPL T S unit has insufficient memory available to store the sent file, it responds with Fld ] (failed) instead of with Upl ].

 

 

____

 

 

response is followed by a Fwm ] (firmware mismatch) response.

 

 

 

 

Retrieve file from user

EfilenameSF}

1B filename 53 46 0D

{responds with 4 bytes of file

 

 

 

flash memory28

 

 

size,+ raw unprocessed data

 

 

 

 

 

 

in file}

 

 

 

Load files to user

Use a POST command on port 80 by the delimited data to be written to the flash file memory.

 

 

 

flash memory

 

 

 

 

 

 

Retrieve file from user

Send a page GET on port 80 followed by: WSF

{responds with raw

 

 

 

flash memory

 

 

unprocessed data in file}

 

 

 

Example:

http://192.168.254.254/mypage.html?cmd=WSF

{data from the file mypage.html.}

 

 

 

 

 

 

 

 

 

Reset (zap)/erase commands

 

 

 

 

 

Erase all files from

E ZFFF}

W ZFFFpf]

Zpf]

 

 

 

flash memory24

 

 

 

 

 

 

Reset all device

E ZXXX}

W ZXXX

Zpx]

The “reset all settings” command does not

settings to factory

 

 

 

affect IP settings or flash memory.

 

 

defaults24

NThis is a product-dependent reset: flex I/O defaults back to TTL input, contact closure defaults to open, relays are reset to open, current sensing thresholds are reset to default, receive time-outs are reset back to defaults, port redirects are terminated. Consult product-specific documentation for settings affected and default values. Excludes IP settings such as IP address, subnet mask, gateway IP address, and IP security-level table, and does not remove the file system.

Absolute system reset, E ZY}

W ZY

Zpy]

but retain IP24

 

 

NThis command is intermediate between the ZXXX and ZQQQ commands. It is an absolute system reset excluding IP settings (IP address, subnet mask, gateway IP address, unit name, DHCP settings, port mapping). This allows you to maintain communication with the device. This reset is recommended after a firmware update. It erases the file system.

N

Firmware can be updated by using this command to upload an

.

s19 file to the

IPL T S

device

.

If the

IPL T S unit determines that the file is not intended for its model, the Upl

]

Page 57
Image 57
Extron electronic IPL T S manual Edf, Stream files via Telnet or RS-232

IPL T S specifications

The Extron Electronics IPL T S is a powerful tool designed for seamless integration and control in AV applications. It provides a complete AV control solution that is highly intuitive and customizable. With its diverse set of features, the IPL T S caters to various environments, from educational institutions to corporate settings, delivering functionality and flexibility.

One of the standout features of the IPL T S is its user-friendly interface, which allows users to easily navigate through different control options. The device supports customizable touchscreen control, enabling users to personalize layouts according to their specific needs. This adaptability not only enhances user experience but also increases efficiency during presentations or meetings.

The technology behind the IPL T S includes advanced network control capabilities. It utilizes Extron’s well-rounded Global Viewer® technology, allowing users to manage and monitor their AV systems through a web-based application. This feature is crucial for IT managers or AV administrators who need real-time insight into the performance and status of their equipment, ensuring seamless operation.

Connectivity is another critical aspect of the IPL T S. It supports various control protocols, including IP, RS-232, and USB, making it compatible with a wide range of third-party devices. This compatibility not only simplifies integration but also offers users the flexibility to expand their AV systems as needed.

Moreover, the IPL T S is designed with robust security features, ensuring that control systems remain secure from unauthorized access. This is particularly important in corporate environments where sensitive information may be presented during meetings.

The device is built with reliability in mind, featuring Extron’s renowned quality assurance processes. It’s designed for uninterrupted performance, ensuring that users can rely on it during critical situations. Additionally, the IPL T S is backed by Extron’s extensive technical support, providing users with peace of mind.

In summary, the Extron IPL T S is an advanced, versatile AV control solution that greatly enhances the user experience in various settings. With its intuitive interface, extensive connectivity options, robust security features, and reliable performance, it stands out as an essential tool for modern AV applications, streamlining control and enabling effective communication.