Extron electronic MAV manual RS-232/422 connection, External sync connection, Installation, cont’d

Models: MAV

1 72
Download 72 pages 8.74 Kb
Page 22
Image 22
Figure 2-8 — Captive screw connector wiring for audio output
9 6 Female
6 9
Male

Installation, cont’d

Tip RS-232/422 connection See warning MCP 1000 Remote Control Panel User’s Manual and the MKP 1000 User’s Sleeve External sync connection Tip 2-6 MAV Series Switchers • Installation

See warning Manual background

Tip

Ring

Sleeve (s)

Tip

Ring

Unbalanced Output

Balanced Output

Figure 2-8 — Captive screw connector wiring for audio output

Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative (-) terminal will damage the audio output circuits.

By default, the audio output follows the video switch. Audio breakaway, which is commanded via the front panel (see chapter 3) or under RS-232/422 control, via the SIS or Windows-based control program, allows you to select from any one of the audio input sources. See chapter 3, Operation, chapter 4, Programmer’s Guide, and chapter 5, Matrix Software for details.

RS-232/422 connection

6RS-232/RS-422 connector — Connect a host device, such as a computer or

 

 

 

 

touch panel control, to the MAV via this 9-pin

5

1

1

5

D connector for serial RS-232/RS-422 control.

If desired, attach an MCP 1000 remote control panel master unit to the switcher’s RS-232/ RS-422 connector. You can also attach an MKP 1000 remote keypad or MCP 1000 slave unit to the MCP 1000 master unit. Refer to the

MCP 1000 Remote Control Panel User’s Manual and the MKP 1000 User’s

Manual for details.

See chapter 4, Programmer’s Guide, for definitions of the SIS commands and chapter 5, Matrix Software for details on how to install and use the control software.

The MAV switchers are factory configured for RS-232 control. To use the switcher under RS-422 control, an internal cable must be moved. See appendix B for the procedure for shifting the cable.

External sync connection

When the switcher switches between inputs, the resulting change in image should be seamless, or clean. Video models of the MAV 1616/168 Series switcher can use an external signal to synchronize switching during the vertical interval. Without the external sync locking feature, switching between inputs can result in a brief rolling (sync loss) or a brief change in the picture size.

7External Sync In connector — Connect an external sync signal to this BNC connection for genlocking the video signal in broadcast or other sync-critical applications.

External Sync Out connector — Connect any downstream equipment that requires genlocking to this BNC connector to route the external sync signal throughout the system in broadcast or other sync-critical applications.

Figure 2-9 shows a basic external sync configuration. The Ext Sync In connector receives a timing signal. The Out connector allows the signal to be passed on to another video device, if required.

2-6 MAV Series Switchers • Installation