Switcher Error Responses

RAM Test FailedUsing the Command/Response Table

ROM Checksum FailedMAV Series Switchers • Programmer’s Guide

EEPROM Reset (Presets/Attenuators)Manual background

Serial EEPROM Reset (Current Settings)Manual background

Invalid JumpersManual background

If an error occurs during powerup, the switcher initiates one or more of the messages listed above.

All Configuration Memory ClearedManual background

The memory cleared message is initiated by the switcher when a system reset has occurred. See System reset to factory defaults in chapter 3.

The switcher does not expect a response from the host, but, for example, the host program might request a new status.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number (too large)

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E17 — Timeout (only caused by direct write of global presets)

Using the Command/Response Table

The command/response table begins below. Lower case letters are acceptable in the command field only where indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table.