VersaTools® MTP DA4 and MTP DA8, cont’d
Furniture mounting
Do not attach the rubber feet. Furniture mount the DA using the optional mounting kit (part
1. | Remove rubber feet if they were previously installed on |
| the bottom of the DA. |
2. | Attach the furniture mounting brackets to the DA with the |
| provided machine screws (figure 5). |
Figure 5 — Attaching the furniture mounting brackets to an MTP DA
3. | Hold the DA with the attached brackets against the |
| underside of the table or other furniture. Mark the |
| location of the screw holes of the bracket on the mounting |
| surface. |
4. | Drill 3/32" (2 mm) diameter pilot holes, 1/4" (6.3 mm) |
| deep in the mounting surface at the marked screw |
| locations. |
5. | Insert #8 wood screws into the four pilot holes. Tighten |
| each screw into the mounting surface until just less than |
| 1/4" of the screw protrudes. |
6. | Align the mounting screws with the slots in the brackets |
| and place the DA against the surface, with the screws |
| through the bracket slots. |
7. | Slide the DA slightly forward or back, then tighten all four |
| screws to secure the unit in place. |
Connections
CAUTION |
| Do not connect these devices to a computer data or | |||||||
|
| telecommunications network. | |||||||
MTP DA8 |
|
|
|
|
|
|
|
| |
A/V INPUT |
|
|
| A/V OUTPUTS |
|
|
| ||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
POWER | |||||||||
+ - |
|
|
|
|
|
|
| OUTPUT MUTE |
12V | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | A |
0.93A MAX |
1 | 2 | 3 | 4 |
MTP DA4
| A/V INPUT |
| A/V OUTPUTS |
| ||
POWER | 1 | 2 | 3 | 4 | ||
| ||||||
+ - |
|
|
|
| OUTPUT MUTE |
12V | 1 | 2 | 3 | 4 | A |
0.93A MAX |
1 | 2 | 3 | 4 |
Figure 6 — DA rear panel features
1Power connector — Plug the included external 12 VDC power supply into this
2A/V Input connector — Connect one end of the cable, carrying the video and audio or serial TP link from the transmitting device, to this
See TP cable termination, on page 11, to wire the
3A/V Output connector — Connect one end of a , carrying the video and audio or serial TP link from the transmitting device, cable to this
Connect the free end of the same cable, carrying the distributed video and audio or serial TP link, from the DA to the receiver.
See TP cable termination, on page 11, to wire the
The MTP DA’s output does not provide any
See the recommended transmission ranges in the table on page 3. The table’s recommendations apply to a complete transmission system, which can include a single transmitter, DA, and multiple receivers or a complex system including multiple
® ® | ®® | 9 |
8 VersaToolsVersaToolsMTPMTPDA4DA4andandMTPMTPDA8DA8• Installation• TP Cable Advantages | VersaToools MTPDA4andMTPDA8••ConnectionsInstallation |