Extron electronic MTPX PLUS 3216 EX@ *X +Oseq, EX@ *X -Oseq, EX@ Oseq, EX1Opek, EX1@ Opol

Models: MTPX PLUS 3232 MTPX PLUS 1632 MTPX PLUS 3216 MTPX PLUS 816 MTPX PLUS 1616 MTPX PLUS 168 MTPX PLUS 128

1 30
Download 30 pages 18.06 Kb
Page 19
Image 19
1 (matrix sizes 1616 and smaller)
1 or 2 (matrix sizes 1632 and larger)
X1#= Local video output number
0 = H- / V- (default)
1 = H+ / V-
2 = H- / V+
3 = H+ / V+
4 = NTSC (no sync stripping)
N X1@= Local output sync polarity
X1@]
EX1#Opol}
Read local output sync settings (matrix size 1616 and smaller) Read local output sync settings (matrix size 1632 and larger)
EOpol}
X1@]

4-8

Command

ASCII command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

Refer also to the MTPX Plus User’s Manual

MTPX Plus Series • Remote Control

Output skew adjustment

Set all output skew adjustment

EX@*X**X**X*Oseq}

OseqX@*X**X**X*]

values

 

 

Example:

E2*0*0*4Oseq}

Oseq02*0*0*4]

Increment one output skew

EX@*X(+Oseq}

OseqX@*X**X**X*]

adjustment value

 

 

Decrement one output skew

EX@*X(-Oseq}

OseqX@*X**X**X*]

adjustment value

 

 

Example:

E2*2*-Oseq}

Oseq02*0*0*3]

Read output skew adjustment

EX@Oseq}

X**X**X*]

values

 

 

Set a specific skew adjustment for the TP output. X* values are listed in RGB order. Set output 2’s skew settings as follows:

Red = 0 ns Green = 0 ns

Blue = 8 ns (delayed 8 ns).

Increase the X( skew plane adjustment for output X@ by 1 step (2 ns).

Decrease the X( skew plane adjustment for output X@ by 1 step (2 ns).

Decrease the blue skew for output 2 by 2 ns (from 8 ns to 6 ns).

at www.extron.com.

Refer also to the MTPX Plus User’s Manual at www.extron.com.

and Optimizing the Video

MTPX Plus Series • Remote Control and Optimizing the Video 4-9

Output pre-peaking

Set output pre-peaking on

EX1)*1Opek}

OpekX1)*1]

Pre-peak the TP output.

Set output pre-peaking off

EX1)*0Opek}

OpekX1)*0]

Do not pre-peak the TP output.

Read output pre-peaking setting

EX1)Opek}

X1!]

 

 

 

 

N X@= Output number

01 – (maximum number of inputs for your model)

 

X*= Skew adjustment range

00 – 31 (each step = 2 ns)

 

X(= Video plane

0

= red, 1 = green, 2 = blue

 

X1)= Pre-peakable output number 01 – half of the outputs for your matrix switcher model (such as 04 for MTPX Plus 168)

X1!= Pre-peaking

0

= off

 

 

 

1

= on

 

 

Command

ASCII command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

Local video output sync polarity

NThe command structure differs, depending on the size of the matrix. Matrix sizes 1616 and smaller, excluding the MTPX Plus 128, do not need the local output variable (X1#). The MTPX Plus 128 and matrix sizes 1632 and larger require the variable.

Set local output polarity

EX1@Opol}

OpolX1@]

Set the horizontal and vertical sync

(matrix size 1616 and smaller)

 

 

polarity for a local output.

Example:

E0Opol}

Opol0]

Set the local output to output negative

 

 

 

horizontal and vertical sync.

Set local output polarity

EX1#*X1@Opol}

OpolX1#*X1@]

Set the horizontal and vertical sync

(matrix size 1632 and larger)

 

 

polarity for local output X1#.

Example:

E2*0Opol}

Opol2*00]

Set local output 2 to output negative

 

 

 

horizontal and vertical sync.

Remote Control and Optimizing the Video, cont’d

Page 19
Image 19
Extron electronic MTPX PLUS 3216 EX@ *X +Oseq, EX@ *X -Oseq, EX@ Oseq, EX1Opek, EX1@ Opol, EX1# *X1@ Opol OpolX1# *X1@