Setup Guide — P/2 DA8 and P/2 DA12 Series (cont’d)
Step 7 (P/2 DA8 A and P/2 DA12 A models only)
Connect up to eight (P/2 DA8 A) or twelve (P/2 DA12 A) audio output devices to the 3.5 mm
Tip | L | Tip |
|
| |
NO GROUND HERE. | Left | Ring |
Sleeve(s) |
| Sleeve(s) |
Tip | R | Tip |
|
| |
NO GROUND HERE. | Right | Ring |
|
L R
Left
Right
Unbalanced Stereo Output | Balanced Stereo Output |
CAUTION For unbalanced audio, connect the sleeve(s) to the center contact ground. DO NOT connect the sleeve(s) to the negative
Configuration
Sync impedance DIP switches
Set the front panel DIP switches to correct for sync impedance mismatches, or to solve laptop compatibility issues on the video input or reflection problems on the video output.
SYNC IMPEDANCE
1 2 3 4 5 6 7
ON | ON |
|
|
|
|
|
|
OFF | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|
Switch 1 (sync input impedance) — The default setting is Off (510 ohms). If the image from the laptop is unstable, slide DIP switch 1 to On (10k ohms).
Switches
Switch | Function | Sync Impedance (ohms) | |
|
|
|
|
|
| On | Off |
|
|
|
|
1 | Input sync | 10,000 | 510 |
2 | Output 1 and 2 sync | 75 | 50 |
3 | Output 3 and 4 sync | 75 | 50 |
4 | Output 5 and 6 sync | 75 | 50 |
5 | Output 7 and 8 sync | 75 | 50 |
6 | Output 9 and 10 sync | 75 | 50 |
7 | Output 11 and 12 sync | 75 | 50 |
|
|
|
|
NSwitches 6 and 7 are available only on the P/2 DA12 series models.
Mute control
The mute control provides a way to mute individual outputs, or all outputs at once. Audio and video for each output are muted simultaneously.
Each output is assigned to a pin on the captive screw connector. To mute any output, short its pin to the ground pin (). Multiple outputs can be shorted at the same time. To mute all outputs at once, short pin A (all) to the ground pin.
MUTE
A | 1 | 3 | 5 | 7 | 9 | 11 |
2 4 6 8 10 12
The P/2 DA8 A model uses two
The P/2 DA12 A model (shown at right) uses two
If you have problems with the output from any of these distribution amplifiers, please consult the Troubleshooting section of the full manual, which is available online at www.extron.com.
If the problems persist, contact the Extron service department.
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East | Extron Europe | Extron Asia | Extron Japan |
+800.633.9876 | +800.3987.6673 | +800.7339.8766 | +81.3.3511.7655 |
Inside USA / Canada Only | Inside Europe Only | Inside Asia Only | +81.3.3511.7656 FAX |
+1.919.863.1794 | +31.33.453.4040 | +65.6383.4400 |
|
+1.919.863.1797 FAX | +31.33.453.4050 FAX | +65.6383.4664 FAX |
|
© 2010 Extron Electronics. All rights reserved.
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
Rev. A
01 10