Extron electronic Configuration, P/2 DA8 A and P/2 DA12 A models only, Mute control, Switch

Models: P/2 DA12 P/2 DA8

1 2
Download 2 pages 30.64 Kb
Page 2
Image 2
Setup Guide —­ P/2 DA8 and P/2 DA12 Series (cont’d)

Setup Guide —­ P/2 DA8 and P/2 DA12 Series (cont’d)

Step 7 (P/2 DA8 A and P/2 DA12 A models only)

Connect up to eight (P/2 DA8 A) or twelve (P/2 DA12 A) audio output devices to the 3.5 mm 5-pole captive screw connectors. Outputs can be balanced or unbalanced.

Tip

L

Tip

 

 

NO GROUND HERE.

Left

Ring

Sleeve(s)

 

Sleeve(s)

Tip

R

Tip

 

 

NO GROUND HERE.

Right

Ring

 

Step 7 (P/2 DA8 A and P/2 DA12 A models only)ConfigurationL R

Left

Right

Unbalanced Stereo Output

Balanced Stereo Output

CAUTION For unbalanced audio, connect the sleeve(s) to the center contact ground. DO NOT connect the sleeve(s) to the negative (-) contacts.

Configuration

Sync impedance DIP switches

Set the front panel DIP switches to correct for sync impedance mismatches, or to solve laptop compatibility issues on the video input or reflection problems on the video output.

SYNC IMPEDANCE

1 2 3 4 5 6 7

ON

ON

 

 

 

 

 

 

OFF

1

2

3

4

5

6

7

 

Switch 1 (sync input impedance) — The default setting is Off (510 ohms). If the image from the laptop is unstable, slide DIP switch 1 to On (10k ohms).

Switches 2-7 (sync output impedance) — Each of these switches controls a pair of outputs simultaneously (see the table below). The default setting is Off (50 ohms). If the front LED is green and all the input and output cables are connected correctly, but there is no image on the display, slide the switch to On (75 ohms).

Switch

Function
Sync Impedance (ohms)

 

 

 

 

 

 

On

Off

 

 

 

 

1

Input sync

10,000

510

2

Output 1 and 2 sync

75

50

3

Output 3 and 4 sync

75

50

4

Output 5 and 6 sync

75

50

5

Output 7 and 8 sync

75

50

6

Output 9 and 10 sync

75

50

7

Output 11 and 12 sync

75

50

 

 

 

 

NSwitches 6 and 7 are available only on the P/2 DA12 series models.

Mute control

The mute control provides a way to mute individual outputs, or all outputs at once. Audio and video for each output are muted simultaneously.

Each output is assigned to a pin on the captive screw connector. To mute any output, short its pin to the ground pin (Sync impedance DIP switches). Multiple outputs can be shorted at the same time. To mute all outputs at once, short pin A (all) to the ground pin.

MUTE

A

1

3

5

7

9

11

2 4 6 8 10 12

The P/2 DA8 A model uses two 5-pole, 3.5 mm captive screw connectors.

The P/2 DA12 A model (shown at right) uses two 4-pole, 3.5 mm connectors and two 3-pole, 3.5 mm connectors.

If you have problems with the output from any of these distribution amplifiers, please consult the Troubleshooting section of the full manual, which is available online at www.extron.com.

If the problems persist, contact the Extron service department.

Extron USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

Inside USA / Canada Only

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

© 2010 Extron Electronics. All rights reserved.

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568 +86.21.3760.1566 FAX

Extron Middle East

+971.4.2991800 +971.4.2991880 FAX

68-1475-50

Rev. A

01 10

Page 2
Image 2
Extron electronic Configuration, P/2 DA8 A and P/2 DA12 A models only, Setup Guide -­P/2 DA8 and P/2 DA12 Series cont’d