when power is applied and an overcurrent condition (2.0 amps or more) exists.
Continued operation in an overload condition will cause premature power supply failure.
5Channel Overload LEDs — These rear panel LEDs light red to indicate that an overcurrent condition (0.6 amps or more, or a short circuit) exists for the associated output.
When the Channel Overload LED lights for a specific output, that output is switched off.
Specifications
Power input | 100VAC to 240VAC, 50/60 Hz, 31 watts, |
| internal, |
Power output | (10) 12VDC outputs (maximum current of |
| all outputs 2.0 A ) |
Temperature/humidity | Storage |
| 10% to 90%, |
| Operating +32° to +113°F (0° to +45°C) / |
| 10% to 90%, |
Rack mount | Yes, with optional rack shelf, part |
Enclosure type | Metal |
Enclosure dimensions | 1.75" H x 4.4" W x 8.5" D |
| 4.4 cm H x 11.2 cm W x 21.6 cm D |
Product weight | 1.0 lbs (0.5 kg) |
Shipping weight | 3 lbs (1.4 kg) |
Vibration | ISTA/NSTA 1A in carton |
| (International Safe Transit Association) |
Listings: | UL, CUL |
Compliances: | CE |
MTBF | 30,000 hours |
Warranty | 3 years parts and labor |
Specifications are subject to change without notice.
User’s Guide
|
| Extron Electronics, USA |
| Extron Electronics, Europe |
| Extron Electronics, Asia |
| Extron Electronics, Japan |
|
| 1230 South Lewis Street |
| Beeldschermweg 6C |
| 135 Joo Seng Road, |
| Daisan DMJ Building 6F |
|
| Anaheim, CA 92805 |
| 3821 AH Amersfoort |
| PM Industrial Building |
| |
|
| USA |
| The Netherlands |
| Singapore 368363 |
| |
www.extron.com |
| 714.491.1500 |
| +31.33.453.4040 |
| +65.6383.4400 |
| +81.3.3511.7655 |
| Fax 714.491.1517 |
| Fax +31.33.453.4050 |
| Fax +65.6383.4664 |
| Fax +81.3.3511.7656 | |
|
|
|
|
© 2002 Extron Electronics. All rights reserved.
P/S 100
Universal 12VDC Power Supply
Printed in the USA
07 02