Extron electronic P/S 100 Description, Installation, Rear Panel Connections, Indications

Models: P/S 100

1 2
Download 2 pages 13.45 Kb
Page 2
Image 2
Installation

Installation

Description

The Extron P/S 100 is a 12VDC 2.0 A universal power supply with ten separate outputs on two 10-connector, 3.5mm captive screw connectors. The outputs are rated at 12V, 200 mA each. The universal power supply can power up to ten devices that require 12VDC external power, such as some Extron interfaces and products in the VersaTools™ line of basic distribution amplifiers, switchers, and associated video accessories.

The rack mountable P/S 100 has an internal auto-switchable power supply that can accept 100VAC to 240VAC at 50 Hz to 60 Hz.

Installation

For optional rack mounting, mount up to four P/S 100s on a 19" 1U Universal Rack Shelf (Extron part #60-190-01) (figure 1).

Quarter Rack Width

False Front Panel

Half rack width false front panel uses 2 front holes

 

 

 

(2) 4-40 x 3/16" screws

 

 

 

Use 2 mounting holes

 

 

 

 

P/S

100

on opposite corners

 

 

Figure 1 — Rack mounting the P/S 100

1.

Mount the P/S 100 on the rack shelf, using two 4-40 x 3/16”

 

screws in opposite (diagonal) corners.

2.

If necessary, mount the half rack width false front panel

 

(included with the Universal Rack Shelf) and/or the quarter

rack width false front panel (included with the P/S 100) to the shelf, using two 4-40 x 3/16” screws in the front holes for each panel.

Rear Panel Connections

1Connect the power cables from the various devices that will receive power from the P/S 100 to the 3.5mm captive screw connectors (included) (figure 2).

 

 

5

 

 

 

4

 

 

 

 

 

 

 

 

 

POWER-GREEN

 

 

 

 

 

100-240V -

 

 

OVERLOAD-AMBER

 

 

 

 

 

 

 

 

 

 

2

 

 

 

CHANNEL OVERLOAD

 

 

 

1

2

3

4

5

6

7

8

9

10

 

50/60 Hz 0.9 A MAX

 

12 VDC OUTPUT 200 mA PER CHANNEL

 

 

 

 

 

 

 

 

 

 

 

 

1

3

P/S 100

12 VDC POWER SUPPLY

Figure 2 — P/S 100 front and rear panels

Each captive screw connector has ten poles and can support up to five power supply outputs (figure 3).

 

1

 

 

 

2

 

- wire

3

 

4

 

 

+ wire

 

5

 

 

Power connector

 

 

plastic cover

- wire

 

 

Up to 5 power

 

+ wire

 

supply outputs

Figure 3 — Connecting power cables to P/S 100

2Plug in the P/S 100.

Indications

3Power LED — This front panel LED (figure 3) lights to indicate that the P/S 100 is receiving power.

4Power/Overload LED — This rear panel LED lights green when power is applied and is normal, and lights amber

2

P/S 100 • Installation

P/S 100 • Indications

3

Page 2
Image 2
Extron electronic specifications Description, Rear Panel Connections, P/S 100 Installation, P/S 100 Indications