PS 123, cont’d

WInstallation and service must be performed by a qualified electrician only.

CA UL listed electrical distribution box is recommended for the termination of the conduit opposite the PS 123 power supply. See "UL requirements," below.

UL requirements

The Underwriters Laboratories (UL) requirements listed below pertain to the installation of the flexible conduit onto a PS 123 power supply.

This unit is not to be used beyond its rated voltage range.

This unit must be wired to a UL listed distribution box.

NThe UL approved electrical distribution box is not included with either the PS 123 power supply or the Flexible Conduit Adapter Kit; the installer is responsible for obtaining and installing the box.

This unit must be installed in accordance with the National Electrical Code and with all local codes.

Installing the flexible conduit cable

Install the flexible conduit cable assembly to the PS 123 as follows:

1.

Unplug the IEC power cord.

2.

Remove and retain the two Phillips head screws that

 

secure the EMT plate (figure 3, below) to the PS 123 rear

 

panel.

 

 

EMT Plate

 

 

100-240 50/60Hz 1A MAX.

OUTPUTS

 

 

RED-

 

 

OVERLOAD

 

 

12 VDC TOTAL OUTPUT 3A

 

 

Remove two screws.

Figure 3 — Removing the EMT plate

3.

Remove and retain the six screws that connect the top

 

cover of the PS 123 to its bottom board (figure 4, on the

 

next page).

 

Lift the cover straight up.

Remove three screws on each side.

 

 

 

 

 

 

123

 

 

 

 

 

P/S PP

LY

 

 

 

 

WE

R

SU

 

 

 

 

 

 

 

 

 

C

3A

PO

 

 

 

 

VD

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AD

 

-OVE

RLO

RED

 

 

 

Figure 4 — Removing the top cover

4. Carefully lift the top cover up, taking care not to remove it completely.

CRough handling of the top cover can tear the wiring that connects the front panel LED.

5.

Use the Phillips head end of an Extron Tweeker or a small

 

standard screwdriver to loosen the screws holding the hot

 

and neutral wires on the side of the terminal block nearest

 

the EMT plate opening (figure 5).

 

 

Terminal Block

Hot Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral Terminal Ground Wire Nut

Figure 5 — Terminal block and IEC wiring

6. Unscrew the EMT plate ground wire from the ground wire nut on the bare metal bottom of the PS 123 enclosure.



PS 123 12 VDC, 3 Amp Power Supply • User's Guide

PS 123 12 VDC, 3 Amp Power Supply • User's Guide



Page 7
Image 7
Extron electronic PS 123 manual UL requirements, Installing the flexible conduit cable

PS 123 specifications

Extron Electronics is renowned for its innovative solutions in the realm of audiovisual technology, and the PS 123 power supply exemplifies this reputation. The PS 123 is a reliable power source designed specifically for powering various Extron products, providing essential functionality in a broad range of applications.

One of the standout features of the PS 123 is its capability to deliver 12 volts of DC power with a current rating of up to 3 amps. This robust output ensures compatibility with a variety of devices, including signal processors, switchers, and amplifiers. The power supply is designed for efficiency, offering a compact form factor that allows for easy integration into existing setups.

Incorporating advanced technologies, the PS 123 features short-circuit protection and thermal protection, enhancing the safety and reliability of the system. These mechanisms are crucial in preventing overheating and component failure, making it an ideal choice for mission-critical environments where consistent performance is essential.

The PS 123 is equipped with a universal input voltage range, accommodating voltages from 100 to 240 volts AC. This flexibility allows it to be used in different regions and electrical standards, making it a versatile component for audiovisual setups worldwide. Furthermore, its low-profile design aids in managing space, making it suitable for use in rack-mounted systems and other confined settings.

Another notable characteristic of the PS 123 is its easy installation process. With its simple plug-and-play operation, users can quickly integrate the power supply into their systems without complex setup procedures. The durable construction of the unit ensures long-term reliability, contributing to lower maintenance costs in the long run.

In conclusion, the Extron PS 123 power supply is a vital component for those seeking dependable power solutions within the audiovisual industry. Its combination of robust output, advanced safety features, and user-friendly design makes it an excellent choice for powering Extron devices. As the demand for high-quality audiovisual equipment continues to rise, the PS 123 remains a top contender for industry professionals aiming to enhance their systems’ performance and reliability.