Installation and Operation, cont’d
Through-desk mounting
1. | If rubber feet were installed on the interface, remove them. |
2. | Insert the machine screws (provided in the mounting kit) |
| through the slots in the optional |
| brackets (part |
| to the interface. |
3. | Hold the interface with attached brackets against the |
| underside of the desk/table. With a soft pencil mark the |
| location of holes for screws on the desk. Mark the |
| opening, approximately 1.8” x 8.9” ( 4.6 cm x 22.6 cm). |
4. | Cut out the material from the installation area with a |
| jigsaw. Check the opening size by inserting the interface |
| part way through the hole. If needed, use a saw, file or |
| sandpaper to enlarge the hole. Smooth the edges of the |
| hole with sandpaper. |
5. | Drill 1/4” (6.4 mm) deep, 3/32” (2.38 mm) diameter pilot |
| holes in the desk or table at the marked screw locations. |
| The holes should be drilled from the underside or inside |
| (concealed side) of the furniture, where the interface will |
| be located. |
6. | Attach the interface to the desk with the provided wood |
| screws, as shown in |
| this illustration. |
TSOOB
OC | EL |
LORNT | LVE |
KAEP
|
| X |
| RTECEN |
|
| AG | XS | GIN |
TGV | GAVS |
| GA |
|
| AVG | M |
| |
| 220 | GVTIIN |
|
|
|
|
| RGB |
2 |
|
| Rxi | 202 |
TUNP | HTIWVTG |
|
| |
1 | I |
|
|
|
| PDSA |
|
|
|
Through-desk mounting
7. To adjust the height of the interface within the desk, slide the interface up or down to the desired position, then tighten the screws that attach the brackets to the interface.
Rack mounting
1. | If feet were installed on the bottom of the interface, remove |
| them. |
2. | Place the interface on one half of the 1U (one unit high, |
| 19” wide) optional rack shelf (part |
| front of the interface with the front of the shelf, and align |
| the threaded holes on the bottom of the interface with the |
| holes in the rack shelf. |
3. | Attach the interface to the rack shelf with the two provided |
|
underside of the shelf, and securely fasten them through diagonally opposite corners as shown in the illustration below.
Use 2 mounting holes on opposite corners
False front panel uses 2 front holes
R | 202 Rxi | (2) |
GB |
|
|
|
| VTG |
Rack mounting
4. | Attach the false front panel (provided with the rack shelf) |
| to the unoccupied side of the rack (as shown above), or |
| install a second |
| repeating steps 1 – 3. |
5. | Attach the rack shelf to the rack using four |
| Insert the bolts through #10 beveled washers, then through |
| the holes in the rack ears and rack, as shown above. |
RGB 202 Rxi, RGB 202 Rxi VTG • Installation and Operation | RGB 202 Rxi, RGB 202 Rxi VTG • Installation and Operation |