Extron electronic RGB 202 Rxi VTG Installation and Operation, cont’d, Through-desk mounting

Models: RGB 202 Rxi RGB 202 Rxi VTG

1 21
Download 21 pages 636 b
Page 8
Image 8

Installation and Operation, cont’d

Through-desk mounting

1.

If rubber feet were installed on the interface, remove them.

2.

Insert the machine screws (provided in the mounting kit)

 

through the slots in the optional through-desk mounting

 

brackets (part #70-077-02), and loosely attach the brackets

 

to the interface.

3.

Hold the interface with attached brackets against the

 

underside of the desk/table. With a soft pencil mark the

 

location of holes for screws on the desk. Mark the

 

opening, approximately 1.8” x 8.9” ( 4.6 cm x 22.6 cm).

4.

Cut out the material from the installation area with a

 

jigsaw. Check the opening size by inserting the interface

 

part way through the hole. If needed, use a saw, file or

 

sandpaper to enlarge the hole. Smooth the edges of the

 

hole with sandpaper.

5.

Drill 1/4” (6.4 mm) deep, 3/32” (2.38 mm) diameter pilot

 

holes in the desk or table at the marked screw locations.

 

The holes should be drilled from the underside or inside

 

(concealed side) of the furniture, where the interface will

 

be located.

6.

Attach the interface to the desk with the provided wood

 

screws, as shown in

 

this illustration.

TSOOB

OC

EL

LORNT

LVE

KAEP

 

 

X

 

RTECEN

 

 

AG

XS

GIN

TGV

GAVS

 

GA

 

 

AVG

M

 

 

220

GVTIIN

 

 

 

 

 

RGB

2

 

 

Rxi

202

TUNP

HTIWVTG

 

 

1

I

 

 

 

 

PDSA

 

 

 

Through-desk mounting

7. To adjust the height of the interface within the desk, slide the interface up or down to the desired position, then tighten the screws that attach the brackets to the interface.

Rack mounting

1.

If feet were installed on the bottom of the interface, remove

 

them.

2.

Place the interface on one half of the 1U (one unit high,

 

19” wide) optional rack shelf (part #60-190-01). Align the

 

front of the interface with the front of the shelf, and align

 

the threaded holes on the bottom of the interface with the

 

holes in the rack shelf.

3.

Attach the interface to the rack shelf with the two provided

 

4-40 x 1/8” machine screws. Insert the screws from the

underside of the shelf, and securely fasten them through diagonally opposite corners as shown in the illustration below.

Use 2 mounting holes on opposite corners

False front panel uses 2 front holes

R

202 Rxi

(2) 4-40 x 1/8" screws

GB

 

 

 

 

VTG

Rack mounting

4.

Attach the false front panel (provided with the rack shelf)

 

to the unoccupied side of the rack (as shown above), or

 

install a second half-rack-width device in that side by

 

repeating steps 1 – 3.

5.

Attach the rack shelf to the rack using four 10-32 x ¾” bolts.

 

Insert the bolts through #10 beveled washers, then through

 

the holes in the rack ears and rack, as shown above.

2-4

RGB 202 Rxi, RGB 202 Rxi VTG • Installation and Operation

RGB 202 Rxi, RGB 202 Rxi VTG • Installation and Operation

2-5

Page 8
Image 8
Extron electronic RGB 202 Rxi VTG user manual Installation and Operation, cont’d, Through-desk mounting, Rack mounting