Installation and Operation, cont’d
2.If the picture appears and is stable, but it has ghosting or blooming, verify the video input is properly terminated. If the problem is not resolved by changing the termination, try using a different input cable. Poor quality or damaged cable can cause ghosting or blooming.
3.If the picture still is not displayed correctly, call the Extron S3 Sales and Technical Support Hotline.
If the interface does not respond to horizontal shifting
If the picture does not move on screen when the horizontal shift control knob is rotated, DDSP is in use. Set the DDSP DIP switch to Off.
Interface Mounting