RGB 500 Series • Installation and Operation
RGB 500 Series • Installation and Operation
Installation and Operation, cont’d
•Use the right two pins to increase the output signal and add
100% of the maximum peaking to the signal for very long
cable runs.
Blue Adjustment (50% gain/peaking shown)
Green Adjustment (Unity shown)
Red Adjustment (100% gain/peaking shown)
BLUEGREENRED
Unity
50%1
00%
33-511-01 Rev. A 07 99
Gain/Peaking Adjustment Jumpers
RGB 500 Series Interface
Attaching audio output, power, and
video output cables
Once the switches have been set, attach the cables that will be
inaccessible after installation. These cables should already be
installed in the wall, conduit or furniture. See pages 2-7 and
2-10 for details
1. Plug the wired audio connector into the audio output
female connector on the bottom of the interface.
2. Attach the video and sync output cables to the interface
with BNC connectors. Pay close attention to the order and
location of connectors.
The connectors on the RGB 500 Series interfaces are
arranged in the following order on the bottom of the
enclosure: B, G, R, H/HV, and V.
3. Attach the 12VDC to 24VDC power supply to the interface
via the 3-pole captive screw terminal on the bottom panel.
See pages 2-7 and 2-9 for details. Plug in or connect the
power supply to the AC power outlet. The interface’s
front panel power indicator LED will light.
Attaching adapter plates
The RGB 508 and RGB 568 can have up to 4 optional adapter
plates.
The adapter plates must be ordered separately. They also must
be attached to the faceplate and cabled before the interface is
installed in the wall or furniture. The screws needed for
installing the adapter plates are built into the plates, so no
additional screws will be needed.
2-112-10
1. Insert the adapter plate screws through the holes in the
faceplate. Attach the adapter plates to the faceplate with
the provided captive washers and #4-40 nuts.
Installing optional adapter plates
2. Attach the output cables to the back side of the adapter
plate(s). Several adapter plates require conductors to be
soldered to the connectors. Attach foil and braided shields
to ground connections.
RGB 568
INPUT
BUFFERED
LOCAL MONITOR
POWER
AUTO
ID PIN 11
ID PIN 4
CS PIN 9
H. SHIFT
AUDIO
WITH ADSP
TM
#4-40 Nut w/ Captive
Washer
RGB 508
RGB 568
(up to 4 Plates)