Specifications

SPA 12 AAP Installation Guide

The magnet cap and rear enclosure pieces work best with mounting options where ample room is provided for them. Some four-space AAP architectural frame products are too small to allow for these optional pieces, and some wall mount situations may present an obstruction. In such instances, remove the magnet cap.

To remove the magnet cap

1.Unscrew the two ¼” lock washer nuts that hold the magnet cap in place.

2.Gently pull the magnet cap from the speaker driver.

Although the SPA 12 AAP speaker works properly in free air (without the rear enclosure and magnet cap), it is a good practice to limit open space behind the SPA 12 AAP. Cover large openings as much as possible to optimize the speaker’s performance.

To install the SPA 12 AAP speaker into an Extron architectural frame, do the following. Several of the steps are summarized in figure 4, below.

1.Insert the SPA 12 AAP speaker and front grill into the four- space AAP opening of the architectural frame. Ensure that the SPA 12 threaded standoffs are lined up with the openings of the architectural frame.

4-gang Wall Box

2 Tighten (4) #4-40 Nuts

w/ Captive Washers

3 Speaker Wire

 

J

C

TOR

1

PRO

 

 

 

OFF

ON

 

 

ME

 

 

VOLU

 

 

 

 

 

 

 

AP

 

 

 

 

12 A

Extron

 

 

 

SPA

 

 

 

Extron

MLC 104 AAP

2.Attach #4-40 nuts to both pairs of threaded standoffs emerging from the SPA 12, and tighten them to the architectural frame.

3.Attach the speaker wire pair ends to the SPA 12 AAP speaker by soldering the exposed tips to the speaker’s positive and negative terminal pair (marked – +).

4.Attach the opposite end of the speaker wire to the output of your amplifier.

Specifications

Audio/acoustic and electrical

Speaker type

1-way, full range architectural speaker

Frequency range

350 Hz to 15 kHz, -10 dB, half space

Power capacity

10 W continuous program

 

5 W continuous pink noise

Nominal sensitivity

86 dB SPL, 1 W (2.83 V) @ 1 m, half space

Nominal impedance

8 ohms

Nominal coverage

150° conical coverage

Driver

2.5" (64 mm) full-range

Input connector

(1) solder terminal, 2 pin

General

Package

1 speaker

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

Mounting

Mountable into the four-space AAP

 

opening of an Extron Cable Cubby

 

(models 300C, 300S, 600, 800); an HSA 400

 

or HSA 402; or a mounting frame

 

(AAP 102, AAP 102 FSR, AAP 106 AKM

 

UK, AAP 104, AAP 202)

Enclosure type

Metal faceplate with plastic rear enclosure

Enclosure

 

Faceplate

2.8" H x 3.5" W x 0.1" D (71 mm H x

 

89 mm W x 3 mm D) (four space AAP

 

plate)

Device

2.8" H x 3.5" W x 2.5" D (71 mm H x

 

89 mm W x 64 mm D)

SPA 12

Front Grill

Figure 4 — Mounting the SPA 12 into an MLC 104

6

SPA 12 AAP Speaker • Installation Guide

SPA 12 AAP Speaker • Specifications, part numbers, accessories

7

Page 7
Image 7
Extron electronic SPA 12 AAP manual Specifications, Audio/acoustic and electrical, General, Mounting the SPA 12 into an MLC