VNR 100 • Setup Guide (Continued)
1.Use a computer connected to the same network as the VNR 100. In the browser address bar, enter the IP address of the recorder, followed by a colon (:) and the port number. By default, this is 192.168.254.254:8080. Contact your network administrator to be sure these values have not changed.
The login screen opens (see figure at right).
2.Enter the Username and Password.
NOTE: By default, both the Username and Password are config.
3.Click Login. The VNR 100 Recorder Settings page opens (see figure at right).
4.Enter the IP Address, Subnet Mask, and Gateway Address of the recorder.
5.Enter the Controller IP address, Controller port number and maximum transmission unit (MTU) setting for the controller. Contact your network administrator to ensure you have the correct values.
ATTENTION: The VNM Enterprise Controller port number is used by all
Under normal circumstances, the setting should remain at the default value (5432).
6.Enter a New password and Confirm New password.
7.Click Apply Changes to save the settings (or Cancel Changes to exit without saving the information).
|
|
| Logout |
|
| VNMatrix recorder settings |
|
|
| Network settings [eth0] |
|
IP Address |
| 192.168.254.254 |
|
Subnet Mask | 255.255.255.0 |
| |
Gateway |
| 192.168.254.253 |
|
|
| Recorder settings |
|
Serial |
| 1111999 |
|
Controller IP |
| 192.168.254.254 |
|
Controller port | 5432 |
| |
MTU |
| 1500 |
|
|
| User settings |
|
New password |
|
| |
Confirm New password |
|
| |
|
| Data disk |
|
Umount | status: | mounted to /home/matrix_rec/Recording_Files | |
Disk free space: |
| ||
Format |
| formated to ext3 |
|
|
| Apply Changes | Cancel Changes |
Getting Started with VNM Enterprise Controller
The VNM Enterprise Controller must be on the same network as the VNR 100.
1. | Use a PC on the same network as the controller to access the controller website. In |
| the browser address bar, enter the controller IP address. The Login screen opens (see |
| figure at right). |
2. | Enter the Username and Password. |
| NOTE: By default, for the VNM Enterprise |
| Controller, the Username is admin. Leave |
| the Password blank (no entry is required). |
3. | Click Login. The Enterprise Controller device list |
| opens (see the figure to the right). |
4. | Check the box next to the VNR 100 recorder. A |
| series of action buttons appear at the bottom of |
| the screen (see figure below). |
| See the Enterprise Controller User Guide (at |
| www.extron.com) for complete information |
| about configuring and using the VNR 100. |
Extron Headquarters |
| Extron Europe | Extron Asia | Extron Japan | Extron China | Extron Middle East | Extron Korea | Extron India |
+1.800.633.9876 (Inside USA/Canada Only) | +800.3987.6673 | +65.6383.4400 | +81.3.3511.7655 | +86.21.3760.1568 | +971.4.299.1800 | +82.2.3444.1571 | 1800.3070.3777 | |
Extron USA - West | Extron USA - East | (Inside Europe Only) | +65.6383.4664 FAX | +81.3.3511.7656 FAX | +86.21.3760.1566 FAX | +971.4.299.1880 FAX | +82.2.3444.1575 FAX | Inside India Only |
+1.714.491.1500 | +1.919.850.1000 | +31.33.453.4040 |
|
|
|
|
| +91.80.3055.3777 |
+1.714.491.1517 FAX | +1.919.850.1001 FAX | +31.33.453.4050 FAX |
|
|
|
|
| +91.80.3055.3737 FAX |
|
|
|
|
|
|
|
|
|
© 2013 Extron Electronics All rights reserved. www.extron.com | |
4 | 05 13 |
|