Installation and Operation, cont’d
| are set for the formats that match the cable configuration |
| and the requirements of the display/recording devices. |
4. | Verify that the 75 Ohm video input termination DIP |
| switch has been set correctly. |
5. | To test the system setup and output, substitute a video |
| test generator for the computer input. |
6. | Confirm that the input is receiving a signal with a com- |
| patible scan rate (horizontal frequency between 24 kHz |
| and 70 kHz, and a vertical frequency of 50 Hz to 120 Hz). |
7. | Call Extron’s customer support hotline if needed. Be |
| prepared to discuss the steps you have taken and the |
| equipment involved. |
If the image does not display correctly
Symptoms | Solutions | ||
The picture is | Adjust the centering and sizing controls | ||
shifted off the | |||
( , | ). | ||
screen edges. | |||
|
| ||
|
|
| |
The image is | Change the 75 ohm/high Z video input | ||
stable, but it has | |||
termination. If that doesn’t solve the | |||
ghosting or | |||
problem, use a different input cable. | |||
blooming. | |||
|
| ||
|
| ||
| Video input may be | ||
| a local monitor or a termination adapter is | ||
The picture is | attached to the local monitor output | ||
faint or cuts out, | connector, make sure that the 75 Ohm | ||
and the signal is | video input termination DIP switch is set | ||
weak. | to Off (for high Z termination). | ||
| Disconnect all unused output cables. Do | ||
| not connect cables to both the | ||
| RGB/component outputs at the same time. | ||
|
| ||
| Adjust the hue/tint and color controls on | ||
The picture | the display device. | ||
appears without | Make sure that the video display/ | ||
color. | recording equipment is using the same | ||
| standard (NTSC or PAL) as the VSC 150. | ||
|
|
| |
In a genlocked |
|
| |
system, | The color subcarrier phase (Sub Phase) | ||
displayed color | might require readjustment. | ||
is incorrect. |
|
| |
|
|
| |
The image still |
|
| |
does not display | Call Extron’s customer support hotline. | ||
correctly. |
|
| |
|
|
|
If the scan converter does not respond to controls
Symptoms | Solutions | |
|
| |
The picture does not move | The VSC 150 may be set for | |
Executive mode. | ||
on screen when the | ||
| ||
horizontal and vertical | Adjustments can be made via | |
centering controls are | ||
rotated, and the filtering | Executive mode can be turned | |
settings do not change | ||
off by pressing the Freeze and | ||
when the filtering controls | ||
Size controls simultaneously for | ||
are pressed. | ||
2 seconds. See page | ||
| ||
|
| |
| Signals from the IR 601 remote | |
The VSC 150 responds to | control may not be reaching the | |
scan converter. | ||
adjustments made via the | ||
Change the placement of the | ||
front panel, but not to | ||
equipment so the signals have a | ||
selections from the IR | ||
clear transmission path between | ||
remote control. | ||
the remote control and the | ||
| ||
| VSC 150. | |
|
| |
There is no response to | Ensure that the baud rate | |
(9600 baud) and communication | ||
commands from the | ||
protocol are set correctly. See | ||
page | ||
| ||
|
|
VSC 150 • Installation and Operation |