TOOLS NEEDED FOR INSTALLATION
•Saber Saw or Jig Saw
•Drill
•1 1/4" Wood Drill Bit
•Pliers
•Phillips Screwdriver
•Flat Blade Screwdriver
•Wire Stripper or Utility Knife
•Metal Snips
•Measuring Tape or Ruler
•Level
•Pencil
•Caulking Gun
•Duct Tape
PARTS SUPPLIED FOR INSTALLATION
•1 Backdraft Damper
•4 Black Screws & 4 Silver Screws
•1 Literature Package
PARTS NEEDED FOR INSTALLATION
•2 Conduit Connectors
•Power Supply Cable
•1 Wall or Roof Cap
•All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
•Charcoal Filters
For
part # 6093032 PLAN THE DUCTWORK
The Agio convertible rangehood is designed to offer wide flexibility of installations. The rangehood can be ducted vertically or horizontally through a 3 1/4" X 10" rectangular vent. The unit can also be installed in a ductless recirculating configuration. FIGURES 1 and 2 show horizontal and vertical duct installations for this rangehood. FIGURE 3 shows the exhaust opening for ductless installation.
HORIZONTAL
DUCTING
FIGURE 1
VERTICAL
DUCTING
FIGURE 2
DUCTLESS
INSTALLATION
FIGURE 3
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 25 equivalent feet if ducted with the required minimum of 3 1/4" by 10" rectangular duct. Calculate the length of the ductwork by adding the equivalent feet in FIGURE 4 for each piece of duct in the system.An example is given in FIGURE 5. For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible.
45˚ Elbow | 3.0 feet |
| 9 | Feet Straight Duct |
| 9.0 feet | |
90˚ Elbow | 5.0 feet |
| 2 | - 90˚ Elbows | 10.0 feet | ||
90˚ Flat Elbow | 12.0 feet |
| Wall Cap |
| 0.0 feet |
| |
Wall Cap | 0.0 feet |
| Total System | 19.0 feet | |||
FIGURE 4 |
|
|
| FIGURE 5 |
|
|
|
PLAN THE DUCTWORK
First, determine which venting option will be used:
•Horizontal
•Vertical
•Ductless
For Horizontal and Vertical ducting, the ductwork cutout dimensions are given in FIGURE 6. For ductless installations, read the section discussing ductless installations before you make any cutouts or modifications to the rangehood. Ductless installations require Charcoal Filters.
30" or 36" or 23 5/8" (60 cm)
30" or 36" or 23 5/8" (60 cm)
FIGURE 6
Version 10/05 - Page 4