FUSE REPLACEMENT (IF NEEDED)

WIRING DIAGRAM

• This rangehood uses 20 watt halogen lamps.

FUSE REPLACEMENT (IF NEEDED)

FUSE: Model 5 X 20 5A time delay

1.Remove the filters

2.Remove the screws fixing the fuseholder box.

3.Open the fuseholder (bayonet fixing)

4.Replace the fuse with another of the same type

5.Replace the fuseholder box and the filters

 

 

 

 

 

 

FIGURE 14

FIGURE 15

 

 

 

 

USE AND CARE INFORMATION

Thisrangehoodsystemisdesignedtoremovesmoke,cooking vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

Rangehood Control Panel

Thecontrolpanelislocatedonthefrontedgeoftherangehood.

The position and function of each control button are indicated

in FIGURE 9.

FIGURE 9

Light On/Off Button ( L )

On/Off switch for the halogen lights. Push the button in to turn the light ON, push again to turn the light OFF.

Blower Indicator Light ( I )

Lights up to indicate blower is ON.

Blower On/Off and Speed Buttons ( 1, 2, 3 )

Push button (1) to turn ON and OFF the blower. This button must be pushed in for the blower to operate regardless of speed chosen. Button (1) operates the blower on LOW speed. Push button (2) for MEDIUM speed. Push button

(3) for HIGH speed.

Cleaning

The stainless steel grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher. Clean exterior surfaces with a commercially available stainless steel cleaner. Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces.

Replacing the Halogen Lamps

Before you begin, make sure that the rangehood is turned off and that the other lamps have had sufficient time to cool. Halogen bulbs burn extremely hot and serious injury could result from touching a hot bulb. To replace the lamp, pull from it's socket and reinsert new bulb.

An alternative method to replace the lamps is to use a 1 1/4" suction cup (FIGURE 15). Attach the suction cup to the bulb and pull firmly down on the bulb and replace with a new lamp.