ATTACH THE SUPPORT

ATTACH THE SUPPORT

1. Put a thick, protective

 

 

covering over cooktop,

 

set-in range or countertop

 

to protect from damage

 

or dirt.

 

2. Determine and clearly

 

mark with a pencil on the

 

ceiling.

wheretherangehood

 

will be installed.

 

3. Atemplate(LinFIGURE

 

6) for mounting the support

 

is supplied in the carton

 

with the support. Use this

 

template to mark holes for

FIGURE 6

support on the ceiling.

 

 

4. Determine and make necessary cuts for the ductwork. The duct opening is shown on the mounting template (L in FIGURE 6). Install ductwork before mounting the support.

5. IfusingtheHighCeiling Chimney Kit, remove the CHIMNEY COVER from the CHIMNEY EXTENSION (A in FIGURE 7). Position the

CHIMNEY EXTENSION over the CHIMNEY SUPPORT(BinFIGURE

7) so that the outside edges and the electrical holes line up. Attach the CHIMNEYEXTENSIONto theCHIMNEYSUPPORT

using the 4 bolts (C inFIGURE 7 FIGURE 7). Tighten bolts

securely.

6.Determine the proper location for the Power Supply Cable as indicated on the template. Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply Cable. Use caulking to seal around the hole. DO NOTturnonthepoweruntilinstallationiscomplete!Aknockoutis provided at the top of the CHIMNEY SUPPORT (D in FIGURE 8).

7.For ducted installations, place the round DAMPER (N in FIGURE 1) into the exhaust opening of the rangehood and press down.

FIGURE 8

8.Attach the CHIMNEY SUPPORT (D in FIGURE 8) to the ceiling. Makesure thatthesupportisfirmlyattached tothe ceiling. Determine the desired length of the support structure and adjust the length of the support by removing the four screws (indicated in FIGURE 8) with a flat head screwdriver. Once the length of the support is determined, install and tighten the four screws.

FOR DUCTLESS INSTALLATIONS

Ductless installations require a Ductless Conversion Kit whose components are pictured in FIGURE 9. Do not use the DAMPER (N in FIGURE 1) for ductless installations. The LOWER CHIMNEY COVER (B in FIGURE 1) should be discarded and replaced by the new one with holes from the DuctlessConversionKit (D in FIGURE 9).

As indicated in

FIGURE

 

9, place the DUCTLESS

 

DIVERTER (A)

over the

 

exhaust opening of the EASY

 

CUBE (E). FittheDUCTLESS

 

DIVERTER EXTENSIONS

 

HORIZONTAL (B) into the

FIGURE 9

DIVERTER (A).

 

 

 

MAKE THE ELECTRICAL CONNECTION

Remove the cover from the field wiring compartment. DO NOT turn on the power until installation is complete! Connect the Power Supply Cable to the rangehood. Connect the Green (Green and Yellow) ground wire under the Green grounding screw. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector.

INSTALLING THE RANGEHOOD

1. The UPPER CHIMNEY

 

COVER (C in FIGURE 10)

 

attaches using two screws

 

provided (G in FIGURE 10).

 

If using the High Ceiling

 

Chimney Kit, use the

 

UPPER CHIMNEY COVER

 

supplied with the kit. Slide

 

up and attach the UPPER

 

CHIMNEY COVER.

 

2. Attach theductworkto the

 

DAMPER (N in FIGURE 1).

 

Make sure to seal all joints

 

with duct tape to prevent

 

leaks.

 

3. The LOWER CHIMNEY

 

COVER (B in FIGURE

 

10) attaches using two

 

screws provided (G in

 

FIGURE 10). Install the

 

LOWERCHIMNEYCOVER

FIGURE 10

For ductless installations, line up the DUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B in FIGURE 9) with the holes in the LOWER CHIMNEY COVER (D in FIGURE 9) and snap in the VENT GRIDS (C in FIGURE 9).