RECIRCULATING INSTALLATIONS
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating installations (FIGURE 1), Charcoal Filters are necessary. Remove all grease filters and set aside. Attach one charcoal filter to each end of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove (FIGURE 1A). Replace all grease filters. Recirculating installations also require some duct work to divert the air out of the top or face of the cabinet or custom hood. The duct work must not terminate inside the cabinet or custom hood.
| ceiling | cabinet | ceiling |
|
|
| |
|
| or |
|
|
| custom |
|
|
| hood | FIGURE 1A |
|
|
| |
cabinet | duct |
| duct |
or |
| ||
custom | work |
| work |
hood |
|
|
|
inca pro 30 |
| inca pro 30 | |
|
|
| FIGURE 1 |
PLAN YOUR DUCTWORK | MAKE YOUR |
To ensure that the blower performs to its highest possible capacity, ductwork should be as short and straight as possilbe.
The ductrun should not exceed 35 equivalent feet if ducted using the required minimum of 6" round duct. Calculate the length of the ductwork by adding the equivalent feet in FIGURE 2 for each piece of duct in the system An example is given in FIGURE 3.
45˚ Elbow |
| 3.0 feet | ||
90˚ Elbow |
| 5.0 feet | ||
90˚ Flat Elbow |
| 12.0 feet | ||
Wall Cap |
| 0.0 feet | ||
| FIGURE 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
9 | Feet Straight Duct |
| 9.0 feet | |
2 | - 90˚ Elbows | 10.0 feet | ||
Wall Cap |
| 0.0 feet |
| |
Total System | 19.0 feet |
FIGURE 3
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible.
1.Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet or custom hood. Put a thick, protective covering over cooktop,
2. Determine and clearly mark with a pencil the center line on the cabinet or custom hood where the rangehood will be installed.
3.Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install the ductwork before the rangehood.
4.Determine the proper location for the Power Supply Cable. Use a 1 1/4" Drill Bit to make this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the power until installation is complete.
5.Make the
28 7/8"
| 14 | |
5/8" | ||
|
FIGURE 4
Version 10/05 - Page 6