VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO

TO PAGE 5.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

!WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- essary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box)

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:InstallationWorkAndElectricalWiringMust Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire ProtectionAssociation (NFPA), and theAmerican Society for Heating, Refrigeration andAir Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not dam- age electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

!WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

DO NOT use this appliance with any solid state fan speed control device.

Failure to follow electrical requirements may result in a fire.

For residential use only.

Version 10/05 - Page 2

Page 2
Image 2
Faber INCA SMART Venting Requirements, Electrical Requirements, Ducted fans must always be vented to the outdoors

INCA SMART specifications

The Faber INCA SMART is an innovative kitchen hood that combines advanced technology with stylish design to elevate the cooking experience. This appliance is not only functional but also serves as an aesthetic addition to modern kitchens. Its sleek, minimalist design ensures that it seamlessly blends into various kitchen decors while providing powerful performance.

One of the key features of the Faber INCA SMART is its powerful extraction capability. The hood is equipped with a high-efficiency motor that effectively removes smoke, odors, and steam from the kitchen, allowing for a pleasant cooking environment. With multiple speed settings, users can easily adjust the extraction power based on their culinary needs, ensuring optimal air quality at all times.

The INCA SMART also boasts advanced air filtration technology. The filters are designed to capture grease and particulates, ensuring the air in the kitchen remains clean and fresh. The grease filters are washable, making maintenance effortless and prolonging the lifespan of the appliance. Additionally, the option for charcoal filters allows for recirculation mode, making it suitable for spaces lacking external ventilation.

A standout feature of the Faber INCA SMART is its smart control system. This technology allows users to operate the hood effortlessly through a simple touch control panel. It features intuitive icons that make it easy to navigate settings, while the sleek lighting enhances visibility in the cooking area. The integrated LED lights not only illuminate the workspace but also consume less energy compared to traditional bulbs, making it an environmentally friendly choice.

Another significant characteristic of the INCA SMART is its low noise level. Faber has designed this kitchen hood to operate quietly, ensuring a peaceful cooking experience. This is particularly beneficial for open-plan living spaces where noise can easily carry between rooms.

Stylish and efficient, the Faber INCA SMART is available in various sizes to accommodate different kitchen layouts. Its versatile design options and advanced features make it a premium choice for homeowners seeking both functionality and aesthetics in their kitchen hoods. This appliance is perfect for anyone looking to enhance their culinary space while ensuring a clean and comfortable environment.